Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: The guarded light pipe is a recently described alternative endoillumination technique to chandelier illumination. We sought to compare the outcomes of scleral buckling (SB) under indirect ophthalmoscopy (ID) to heads-up three-dimensional visualization with a guarded light pipe (3DGLP).
Methods: A retrospective comparative study was performed, including 47 eyes that underwent SB for rhegmatogenous retinal detachment (RRD) repair with either traditional ID (n = 31) or 3DGLP (n = 16).
Results: The single surgery anatomic success rate was 87.0% in the ID group and 87.5% in the 3DGLP group. The final anatomic success rate was 100% in both groups. The median (interquartile range) post-operative logMAR was 0.10 (0.0-0.20) in the ID group and 0.08 (0.02-0.69) in the 3DGLP group (p = 0.51). The median operative time was 107 (94-123) minutes in the ID group and 100 (90-111) minutes in the 3DGLP group (p = 0.25). Among eyes that underwent subretinal fluid drainage, the operative time was significantly longer in the ID group compared to the 3DGLP group, 113 (100-135) minutes vs 93 (85-111) minutes (p = 0.035). There were no post-operative complications in the ID group and one complication of self-resolving vitreous hemorrhage associated with a malfunctioning cryoprobe in the 3DGLP group (p = 0.34). There were no cases of post-operative cataract progression in either group.
Conclusion: Compared to traditional SB, 3DGLP improves ergonomics and educational value with similar anatomical, visual, intra and post-operative outcomes and may result in shorter operative time in cases requiring subretinal fluid drainage.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9507285 | PMC |
http://dx.doi.org/10.2147/OPTH.S378179 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!