Engineered Electroactive Solutions for Electrochemical Detection of Tuberculosis-Associated Volatile Organic Biomarkers.

IEEE Sens J

Department of Chemical Engineering and the Department of Materials Science and Engineering, The University of Utah, Salt Lake City, UT 84112, USA.

Published: February 2022

Rapid screening of tuberculosis by evaluation of associated volatile organic biomarkers in breath is a promising technology that is significantly faster and more convenient than traditional sputum culture tests. Methyl nicotinate (MN) and methyl p-anisate (MPA) have been isolated as potential biomarkers for mycobacterium tuberculosis and have been found in the breath of patients with active pulmonary tuberculosis. A novel approach to detection of these biomarkers in liquid droplets (e.g. from breath condensate) using inexpensive screen-printed electrodes is presented. Previous modelling studies suggest that these biomarkers complex with certain transition metals of particular valence state. This interaction can be exploited by mixing the biomarker sample into an electroactive solution (EAS) containing the functional metal ion and observing the change electrochemically. The study focuses on low biomarker concentrations, determined to be clinically relevant based on preliminary GC-MS studies of the levels found in patient breath. It was found that both the cyclic voltammogram and square wave voltammogram of copper(II) change significantly when as little as 0.1 mM MN is added to the solution, with analysis times of less than 2 min. Copper(II) exhibits three separate peaks during square wave voltammetry. The location and area of each peak are affected differently as the concentration of MN increases, suggesting a reaction with specific oxidation states of the metal. In this way, a "fingerprint" method can be used to identify biomarkers once their known interaction is established.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9495895PMC
http://dx.doi.org/10.1109/jsen.2021.3126732DOI Listing

Publication Analysis

Top Keywords

volatile organic
8
organic biomarkers
8
square wave
8
biomarkers
6
engineered electroactive
4
electroactive solutions
4
solutions electrochemical
4
electrochemical detection
4
detection tuberculosis-associated
4
tuberculosis-associated volatile
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!