Immediate verification of whether a patient being examined is correct is desirable, even if the scan ranges change during different examinations for the same patient. This study proposes an advanced biological fingerprint technique for the rapid and reliable verification of various scan ranges in computed tomography (CT) scans of the torso of the same patient. The method comprises the following steps: geometric correction of different scans, local feature extraction, mismatch elimination, and similarity evaluation. The geometric magnification correction was aligned at the scanner table height in the first two steps, and the local maxima were calculated as the local features. In the third step, local features from the follow-up scout image are matched to those in the corresponding baseline scout image via template matching and outlier elimination via a robust estimator. We evaluated the correspondence rate based on the inlier ratio between corresponding scout images. The ratio of inliers between the baseline and follow-up scout images was assessed as the similarity score. The clinical dataset, including chest, abdomen-pelvis, and chest-abdomen-pelvis scans, included 600 patients (372 men, 68 ± 12 years) who underwent two routine torso CT examinations. The highest area under the receiver operating characteristic curve (AUC) was 0.996, which was sufficient for patient verification. Moreover, the verification results were comparable to the conventional method, which uses scout images in the same scan range. Patient identity verification was achieved before the main scan, even in follow-up torso CT, under different scan ranges.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s12194-022-00682-2 | DOI Listing |
Surg Pract Sci
June 2022
Yale School of Medicine, 330 Cedar Street BB310, New Haven, CT 06510, United States.
Background: Occult pneumothoraces (OPTX) are pneumothoraces that are not seen on chest X-ray (CXR) but visualized on computerized tomography (CT) scan. OPTX are frequently discovered during the initial trauma evaluation, there is a paucity of evidence based guidelines on how they should be further monitored. In this study we hypothesized that the practice of obtaining routine CXR for the surveillance of OPTX does not alter clinical management.
View Article and Find Full Text PDFSe Pu
February 2025
School of Chemistry and Chemical Engineering, Guangxi University, Nanning 530004, China.
To evade legal controls, new psychoactive substances (NPS), which have been designed as substitutes for traditional and synthetic drugs, are gradually dominating the drug market. Synthetic cannabinoids (SCs), which account for the majority of NPS, are rapidly being derivatized; consequently, controlling increasing abuse by merely listing individual compounds is difficult. Therefore, China has included the entire SC category of SCs listed as legal controlled substances since July 1, 2021.
View Article and Find Full Text PDFMed Phys
January 2025
Department of Medical Biophysics, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada.
Background: With increasing evidence supporting three-dimensional (3D) automated breast (AB) ultrasound (US) for supplemental screening of breast cancer in increased-risk populations, including those with dense breasts and in limited-resource settings, there is an interest in developing more robust, cost-effective, and high-resolution 3DUS imaging techniques. Compared with specialized ABUS systems, our previously developed point-of-care 3D ABUS system addresses these needs and is compatible with any conventional US transducer, which offers a cost-effective solution and improved availability in clinical practice. While conventional US transducers have high in-plane resolution (axial and lateral), their out-of-plane resolution is constrained by the poor intrinsic elevational US resolution.
View Article and Find Full Text PDFBMJ Open
January 2025
Department of Medical Imaging, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi, China
Introduction: During the first wave of the COVID-19 outbreak in China, the surge of COVID-19 cases was rapid and drastic. Emerging evidence suggests that beyond the acute phase, patients with COVID-19 may experience a wide range of postacute or long COVID sequelae. However, the mechanism and burden of COVID-19, especially long COVID, have not yet been comprehensively clarified.
View Article and Find Full Text PDFJ Proteome Res
January 2025
Corelabs, King Abdullah University of Science and Technology, Thuwal 23500-6900, Kingdom of Saudi Arabia.
We introduce here a novel approach, termed time-segmented acquisition (Seg), to enhance the identification of peptides and proteins in trapped ion mobility spectrometry (TIMS)-time-of-flight (TOF) mass spectrometry. Our method exploits the positive correlation between ion mobility values and reversed-phase liquid chromatography (LC) retention time to improve ion separation and resolution. By dividing the LC retention time into multiple segments and applying a segment-specific narrower ion mobility range within the TIMS tunnel, we achieved better separation and higher resolution of ion mobility.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!