Formation of chlorate (ClO) and perchlorate (ClO) as by-products in electrooxidation process has raised concern. In the present study, the formation of ClO and ClO in the presence of 1.0 mM Cl on boron doped diamond (BDD) and Magneli phase titanium suboxide (TiO) anodes were evaluated. The Cl was transformed to ClO (temporal maximum 276.2 μM) in the first 0.5 h on BDD anodes with a constant current density of 10 mA cm, while approximately 1000 μM ClO was formed after 4.0 h. The formation of ClO on the TiO anode was slower, reaching a temporary maximum of approximately 350.6 μM in 4.0 h, and the formation of ClO was also slower on the TiO anode, taking 8.0 h to reach 780.0 μM. Compared with the BDD anode, the rate of ClO and ClO formation on the TiO anode were always slower, regardless of the supporting electrolytes used in the experiments, including NaSO, NaNO, NaBO, and NaHPO. It is interesting that the formation of ClO during electrooxidation was largely mitigated or even eliminated, when methanol, KI, and HO were included in the reaction solutions. The mechanism of the inhibition on Cl transformation by electrooxidation was explored.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9508142PMC
http://dx.doi.org/10.1038/s41598-022-19310-5DOI Listing

Publication Analysis

Top Keywords

tio anode
16
formation clo
16
clo
11
formation chlorate
8
clo clo
8
40 h formation
8
anode slower
8
formation
7
tio
5
anode
5

Similar Publications

The development of devices capable of storing energy harnessed from photons is on the rise, owing to the increasing global energy demand for smart systems. The majority of reports in this field cover the use of integrated type devices, which houses a separate photovoltaic module and supercapacitor or battery. Herein, we are reporting a photocapacitor with a simple two-electrode design, capable of operating without a conventional electrolyte or metal ions.

View Article and Find Full Text PDF

Isoelectric Point of Metal Oxide Films Formed by Anodization.

Langmuir

January 2025

Chemistry and Structure of novel Materials, University of Siegen, Paul-Bonatz Strasse 9-11, 57068 Siegen, Germany.

The surface charge of metal oxides is an important property that significantly contributes to a wide range of phenomena, including adsorption, catalysis, and material science. The surface charge can be predicted by determining the isoelectric point (IEP) of a material and the pH of a solution. Although there have been several studies of the IEP of metal oxide (nano)particles, only a few have reported the IEP of metal oxide films.

View Article and Find Full Text PDF

All Light Controlled Five State Logic Gates on a Ferroelectric Ceramic Chip.

Adv Mater

January 2025

State Key Laboratory of High-Performance Ceramics and Superfine Microstructure, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai, 200050, China.

Differentiating photoelectric response in a single material with a simple approach is desirable for all-in-one optoelectronic logical devices. In ferroelectric materials, significantly distinct photoelectric features should be observed if they are in diverse polarization states, unveiling a possible pathway to realize multifunctional optoelectronic logic gates through ferroelectric polarization design. In this study, the Ti self-doping strategy is first applied to 0.

View Article and Find Full Text PDF

Titania (TiO) is one of promising photo catalysts for its high ability to resistant photo corrosion and environmental friendliness, but its photocatalytic activity is too low to be used in industry. To find an approach to solve this problem, graphene oxide (GO), tungsten trioxide (WO) and TiO composite with hollow mesoporous structure was prepared by a two-step spray drying method. The composite was used as raw material to constitute a membrane onto ITO glass to form a membrane photo-anode.

View Article and Find Full Text PDF

The utilisation of implantable medical devices has become safer and more prevalent since the establishment of sterilisation methods and techniques a century ago. Nevertheless, device-associated infections remain a significant and growing concern, particularly in light of the continued rise in the number of medical device implantations. This underscores the imperative for the development of efficacious prevention and treatment strategies for device-associated infections, as well as further investigation into the design of innovative antibacterial surfaces for medical device applications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!