AI Article Synopsis

  • The isolation of circulating tumor cells (CTCs) from blood offers potential benefits for cancer diagnosis and treatment, but challenges like their rarity and diversity have limited clinical use.
  • The researchers developed the MagPure chip, a microfluidic device, which effectively removes white blood cells and isolates highly pure CTC samples while achieving a high recovery rate.
  • This device works well with standard biological studies and allows for a rapid blood processing workflow, making it possible to analyze CTC characteristics that can help assess cancer aggressiveness and prognosis.

Article Abstract

The isolation of circulating tumor cells (CTCs) directly from blood, as a liquid biopsy, could lead to a paradigm shift in cancer clinical care by providing an earlier diagnosis, a more accurate prognosis, and personalized treatment. Nevertheless, CTC-specific challenges, including their rarity and heterogeneity, have hampered the wider use of CTCs in clinical studies. Microfluidic-based isolation technologies have emerged as promising tools to circumvent these limitations but still fail to meet the constraints of high purity and short processing time required to ensure compatibility with clinical follow-up. In this study, we developed an immunomagnetic-based microfluidic device, the MagPure chip, to achieve the negative selection of CTCs through the depletion of white blood cells (WBCs) and provide highly purified samples for subsequent analysis. We demonstrate that the MagPure chip depletes all magnetically labeled WBCs (85% of WBCs were successfully labeled) and ensures a CTC recovery rate of 81%. In addition, we show its compatibility with conventional biological studies, including 2D and 3D cell culture, as well as phenotypic and genotypic analyses. Finally, we successfully implemented a two-step separation workflow for whole blood processing by combining a size-based pre-enrichment system (ClearCell FX1®) with the MagPure chip as a subsequent purification step. The total workflow led to high throughput (7.5 mL blood in less than 4 h) and high purity (947 WBCs per mL remaining, 99.99% depletion rate), thus enabling us to quantify CTC heterogeneity in size and tumor marker expression level. This tumor-marker-free liquid biopsy workflow could be used in a clinical context to assess phenotype aggressiveness and the prognosis rate.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d2lc00443gDOI Listing

Publication Analysis

Top Keywords

magpure chip
16
immunomagnetic-based microfluidic
8
microfluidic device
8
circulating tumor
8
tumor cells
8
liquid biopsy
8
high purity
8
magpure
4
chip immunomagnetic-based
4
high
4

Similar Publications

Article Synopsis
  • The isolation of circulating tumor cells (CTCs) from blood offers potential benefits for cancer diagnosis and treatment, but challenges like their rarity and diversity have limited clinical use.
  • The researchers developed the MagPure chip, a microfluidic device, which effectively removes white blood cells and isolates highly pure CTC samples while achieving a high recovery rate.
  • This device works well with standard biological studies and allows for a rapid blood processing workflow, making it possible to analyze CTC characteristics that can help assess cancer aggressiveness and prognosis.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!