Height Uniformity Simulation and Experimental Study of Electroplating Gold Bump for 2.5D/3D Integrated Packaging.

Micromachines (Basel)

Foshan Blue Rocket Electronics Co., Ltd., Foshan 528051, China.

Published: September 2022

With the rapid development of nano/micro technology for commercial electronics, the typical interconnection method could not satisfy the high power-density packaging requirement. The 2.5D/3D integrated packaging was seen as a promising technology for nano/micro systems. The gold (Au) bump was the frequently used bonding method for these systems because of its excellent thermal, electric, and mechanical performance. However, relatively little work has been performed to analyze its height uniformity. In this study, the simulation and experimental methods were used to analyze the Au bump height uniformity. Firstly, the electroplating process of Au bump under different flow field parameters was simulated by COMSOL software. The simulated results indicated that the Au concentration polarization was the significant reason that caused the non-uniform distribution of Au bump along the wafer radius. Meanwhile, the flow field parameters, such as inlet diameter, inlet flow, titanium (Ti), wire mesh height, and Ti wire mesh density, were optimized, and their values were 20 mm, 20 L/min, 12 mm, and 50%, respectively. Subsequently, the Au bump height uniformity under different current densities was analyzed through an experimental method based on these flow field parameters. The experimental results showed that the increases of current density would decrease the Au bump height uniformity. When the current density was 0.2 A/dm, the average height, range, and deviance values of Au bump were 9.04 μm, 1.33 μm, and 0.43 μm, respectively, which could reach the requirement of high density and precision for 2.5D/3D integrated packaging.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9504247PMC
http://dx.doi.org/10.3390/mi13091537DOI Listing

Publication Analysis

Top Keywords

height uniformity
20
25d/3d integrated
12
integrated packaging
12
bump height
12
flow field
12
field parameters
12
simulation experimental
8
bump
8
gold bump
8
wire mesh
8

Similar Publications

The thermodynamic properties of frozen soil depend on its temperature state and ice content. Additionally, the permeability coefficient significantly affects both the temperature distribution and water movement. In this study, the dynamic variation of soil permeability coefficient with temperature is considered, the permeability coefficient is defined as a piecewise function with temperature as independent variable, and the hydrothermal coupling equation is established.

View Article and Find Full Text PDF

Vertical maxillary excess (VME) is a facial condition characterized by an increased height in the lower third of the face, leading to a longer overall facial appearance. This condition is linked to a significant proportion of malocclusions and is often associated with greater dissatisfaction among patients concerning their appearance. The amalgamation of orthodontics with surgery is a desirable protocol to address VME.

View Article and Find Full Text PDF

Background Obesity is postulated to be a high-risk factor for thrombosis along with the inherent hypercoagulability of pregnancy. The Confidential Review of Maternal Deaths (CRMD) found that thrombosis was one of the major causes of maternal deaths in Kerala. This study investigates the major risk factor - obesity and its association with thrombosis in our study setting, along with other risk factors.

View Article and Find Full Text PDF

Introduction Thoracolumbar fractures, particularly burst fractures, represent a significant health concern due to their prevalence and functional impact. This study evaluates the efficacy of short-segment posterior fixation with intermediate screw instrumentation in treating unstable thoracolumbar fractures. Methods A prospective study was conducted from July 2022 to December 2023, including 26 patients with traumatic thoracolumbar fractures.

View Article and Find Full Text PDF

: Sinus lifting, a procedure to augment bone in the maxilla, may cause complications such as sinusitis due to impaired drainage. This study aimed to assess how sinus lifting impacts airflow in the sinus cavity, which is essential for patients undergoing dental implants. Using computational fluid dynamics (CFD), this research analyzed airflow changes after sinus floor elevation, offering insights into the aerodynamic consequences of the procedure.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!