The detection of and rearrangements is performed for advanced-stage non-small cell lung cancer. Several techniques can be used on cytological samples, such as immunocytochemistry (ICC), fluorescence in situ hybridization (FISH) and, more recently, next-generation sequencing (NGS), which is gradually becoming the gold standard. We performed a retrospective study to compare and rearrangement results from immunocytochemistry, FISH and NGS methods from 131 cytological samples. Compared to NGS, the sensitivity and specificity of ICC were 0.79 and 0.91, respectively, for ALK, and 1 and 0.87 for ROS1. Regarding FISH, the sensitivity and specificity were both at 1 for and probes. False-positive cases obtained by ICC were systematically corrected by FISH. When using ICC and FISH techniques, results are very close to NGS. The false-positive cases obtained by ICC are corrected by FISH, and the true-positive cases are confirmed. NGS has the potential to improve the detection of and rearrangements in cytological samples; however, the cost of this technique is still much higher than the sequential use of ICC and FISH.