Shear-wave elastography (SWE) is widely used in thyroid evaluation, but multiple factors influence thyroid stiffness. Estimating tissue viscosity may enhance the ultrasound diagnosis of thyroid diseases, along with the ultrasound (US) and the SWE assessment. In order to be able to detect diffuse thyroid disease by viscosity measurements, it is essential to firstly define the normal values of thyroid viscosity in healthy subjects. Currently there are no published data on thyroid viscosity measurements. This first prospective study aimed to determine the normal range of thyroid viscosity values in a cohort of healthy thyroids, as well as to determine the factors that may influence them. One hundred and twenty-one consecutive subjects without thyroid pathology were evaluated in the study by means of conventional ultrasound, two-dimensional SWE (2D SWE PLUS) and viscosity plane-wave ultrasound (ViPLUS) embedded in the Supersonic MACH 30 ultrasound system. Five valid tissue viscosity measurements were obtained for each thyroid lobe in every patient and the median values were analyzed and correlated with the biological and demographic parameters of each patient. Our results reveal that ViPLUS is a highly feasible and reproducible technique for thyroid evaluation. Thyroid stiffness, age, gender, BMI and depth of measurements did not influence the thyroid viscosity values. The mean thyroid viscosity by ViPLUS for normal thyroid tissue was of 2.42 ± 0.41 Pa·s. Viscosity assessment by Supersonic ViPLUS is an innovative, non-invasive technique that has proven to be useful for thyroid US evaluation and remains to demonstrate its effectiveness in identifying patients with thyroid disease.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9497532 | PMC |
http://dx.doi.org/10.3390/diagnostics12092194 | DOI Listing |
Curr Med Imaging
January 2025
Department of Medical Ultrasound, The First Affiliated Hospital of Ningbo University, Ningbo, 315010, China.
Objective: This prospective study aimed to establish the typical viscosity range of the thyroid gland in healthy individuals using a new method called the Sound Touch Viscosity (STVi) technique with a linear array transducer.
Methods: Seventy-eight healthy volunteers were enrolled between March, 2023 and April, 2023. Thyroid viscosity was measured using the Resona R9 ultrasound system equipped with a linear array transducer (L15-3WU).
Anatol J Cardiol
September 2024
Department of Endocrinology, The Affiliated Hospital of Southwest Medical University, Luzhou City, Sichuan Province, China.
Background: The aim is to investigate the clinical efficacy of Alprostadil in diabetes mellitus (DM) combined with peripheral atherosclerosis and to investigate the molecular mechanisms.
Methods: Patients included 154 cases with DM combined with peripheral atherosclerosis and were divided into the conventional group (77 cases) and the Alprostadil group (77 cases). Both groups of patients were given conventional treatment, and the Alprostadil group was given Alprostadil treatment on the basis of the conventional group.
Magn Reson Imaging
October 2024
Department of Obstetrics and Gynecology, Institute of Medical Sciences, Medical College, University of Rzeszów, Rejtana 16 C, 35-959 Rzeszow, Poland.
Background: Magnetic resonance elastography (MRE) is a rapidly developing medical imaging technique that allows for quantitative assessment of the biomechanical properties of the tissue. MRE is now regarded as the most accurate noninvasive test for detecting and staging liver fibrosis. A two-dimensional (2D MRE) acquisition version is currently deployed at >2000 locations worldwide.
View Article and Find Full Text PDFClin Respir J
April 2024
Department of Respiratory and Critical Care, Beijing Shijitan Hospital, Capital Medical University, Beijing, China.
Background: Pulmonary mucinous adenocarcinoma is a special type of lung cancer. Its imaging manifestations are diverse, which brings challenges to clinical diagnosis. However, its formation mechanism is unclear.
View Article and Find Full Text PDFFood Chem
August 2024
Department of Thyroid and Breast Surgery, Zhongnan Hospital of Wuhan University, School of Pharmaceutical Sciences, Wuhan University, Wuhan 430071, China; Key Laboratory of Combinatorial Biosynthesis and Drug Discovery (Ministry of Education), School of Pharmaceutical Sciences, Wuhan University, Wuhan 430071, China. Electronic address:
Linoleic acid (LA) detection and edible oils discrimination are essential for food safety. Recently, CsPbBr@SiO heterostructures have been widely applied in edible oil assays, while deep insights into solvent effects on their structure and performance are often overlooked. Based on the suitable polarity and viscosity of cyclohexane, we prepared CsPbBr@SiO Janus nanoparticles (JNPs) with high stability in edible oil and fast halogen-exchange (FHE) efficiency with oleylammonium iodide (OLAI).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!