Technological innovation is the key for surgical progress in knee arthroplasty and improvement in patient outcomes. Exploring patented technologies can help elucidate trends and growth for numerous innovative technologies. However, patent databases, which contain millions of patents, remain underused in arthroplasty research. Therefore, the present study aimed to: (1) quantify patent activity; (2) group patents related to similar technologies into well-defined clusters; and (3) compare growth between technologies in the field of knee arthroplasty over a 30-year period. An open-source international patent database was queried from January 1990 to January 2020 for all patents related to knee arthroplasty A search strategy identified 70,154 patents, of which 24,425 were unique and included analysis. Patents were grouped into 14 independent technology clusters using Cooperative Patent Classification (CPC) codes. Patent activity was normalized via a validated formula adjusting for exponential growth. Compound annual growth rates (CAGR) were calculated (5-year, 10-year, and 30-year CAGR) and compared for each cluster. Overall yearly patent activity increased by 2,023%, from 104 patents in 1990 to 2,208 patents in 2020. The largest technology clusters were "drugs" ( = 5,347; 23.8%), "components" ( = 4,343; 19.0%), "instruments" ( = 3,130; 13.7%), and "materials" ( = 2,378; 10.4%). The fastest growing technologies with their 5-year CAGR were: "user interfaces for surgical systems" (58.1%); "robotics" (28.6%); "modularity" (21.1%); "navigation" (15.7%); and "computer modeling" (12.5%). Since 1990, overall patent growth rate has been greatest for "computer modeling" (8.4%), "robotics" (8.0%), "navigation" (7.9%), and "patient-specific instrumentation" (6.4%). Most patents in knee arthroplasty for the last 30 years have focused on drugs, components, instruments, and materials. Recent exponential growth was mainly observed for user interfaces for surgical systems, robotics, modularity, navigation, and computer-assisted technologies. Innovation theory would suggest that these rapidly growing technologies are experiencing high innovation output, increased resource investments, growing adoption by providers, and significant clinical impact. Periodic monitoring of technological innovation via patent databases can be useful to establish trends and future directions in the field of knee arthroplasty.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1055/s-0042-1756503 | DOI Listing |
Arch Orthop Trauma Surg
January 2025
Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, USA.
Introduction: Knee alignment significantly impacts the outcome of total knee arthroplasty (TKA). Understanding patient perceptions of their knee alignment in relation to objective measurements is essential to ensure optimal surgical outcomes and to meet patients' expectations. This study reports patients' perception of pre- and postoperative knee alignment in relation to radiographic alignment measurements.
View Article and Find Full Text PDFEur J Orthop Surg Traumatol
January 2025
Duzce University, Düzce, Turkey.
Purpose: Blood loss and pain management are significant concerns in total knee arthroplasty (TKA). Tranexamic acid (TA) and cryotherapy have been used separately to address these issues, but their comparative effectiveness is not well studied. This study aimed to evaluate the efficacy of intravenous TA and cryotherapy in reducing blood loss and improving clinical outcomes after TKA.
View Article and Find Full Text PDFJ Clin Med
January 2025
Department of Biomedical and Neuromotor Sciences (DIBINEM), Alma Mater Studiorum University of Bologna, 40123 Bologna, Italy.
Pseudotumors are defined as exuberant non-neoplastic inflammatory masses. This condition can be associated with hip and knee arthroplasty but has not been reported in Total Ankle Arthroplasty (TAA). This paper reports a pseudotumor that formed following TAA, highlighting its clinical presentation, management, and histopathology.
View Article and Find Full Text PDF: The optimal venous thromboembolism (VTE) chemoprophylaxis approach after hip or knee total joint arthroplasty (TJA) remains controversial. This study aimed to characterize antithrombotic-related complications associated with various chemoprophylaxis regimens after TJA and to assess our current institutional risk-stratified prescribing tool. : This retrospective case-control study and regression analysis included elective unilateral TJA patients at a single institution between 1 July 2015 and 31 December 2021.
View Article and Find Full Text PDFJ Clin Med
January 2025
Department of Mechanical Engineering, Yonsei University, Seoul 03722, Republic of Korea.
: Patient-specific instrumentation (PSI) in total knee arthroplasty (TKA) uses preoperative three-dimensional imaging to create cutting blocks tailored to patient anatomy. However, there is debate regarding the additional benefits of PSI in terms of improved alignment or functional outcomes compared to using conventional instruments. Although PSI design has undergone continuous development, the improvements have not been incorporated.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!