Aim: The aim of the study was to assess the effectiveness and safety of the MicroShunt (formerly known as the MIDI-Arrow or InnFocus MicroShunt®), an 8.5-mm-long, 70-μm lumen-controlled ab externo glaucoma filtration surgery device made from poly(styrene-block-isobutylene-block-styrene) (SIBS), in patients with primary open-angle glaucoma (POAG).
Methods: A 2-year, single-center, single-surgeon, nonrandomized, adaptive feasibility clinical study (NCT01563237) was conducted in France from June 2011 to November 2016. Eligible patients were aged 18-85 years and had POAG inadequately controlled on maximum tolerated medical therapy with intraocular pressure (IOP) ≥18 and ≤40 mm Hg. The MicroShunt was implanted ab externo with adjunctive use of mitomycin C (0.2-0.4 mg/mL applied for 2-3 min), alone or in combination with cataract surgery. The primary effectiveness endpoints were the reduction in IOP relative to the preoperative value assessed at each postoperative visit and the measurement of success at years 1 and 2. The primary safety endpoint was the incidence of all procedure- and/or device-related adverse events (AEs) during the study. The secondary effectiveness endpoint was the mean number of glaucoma medications per patient, and the secondary safety endpoint was the incidence of glaucoma reoperation.
Results: Sixty-one eyes from 61 patients underwent MicroShunt implantation. Mean IOP ± standard deviation (SD) was significantly reduced from 25.7 ± 6.1 mm Hg at baseline (N = 61) to 15.8 ± 4.7 mm Hg at year 1 (n = 58) and 16.5 ± 6.0 mm Hg at year 2 (n = 52) (both p < 0.001). Overall success rates for patients achieving IOP ≥6 mm Hg and <21 mm Hg at year 1 and year 2 were 80.3% and 75.4%, respectively. Mean ± SD number of glaucoma medications per patient decreased significantly from 2.9 ± 1.1 at baseline to 0.6 ± 1.0 at year 1 (n = 58) and 1.0 ± 1.3 at year 2 (n = 52) (both p < 0.001). The most common procedure- and/or device-related AEs were investigator-reported increased IOP and hyphema. Four patients required reoperation.
Conclusions: In this study, sustained reductions in mean IOP and number of glaucoma medications from baseline were observed up to 2 years post-surgery. No long-term, sight-threatening AEs were observed.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1159/000526960 | DOI Listing |
Front Oncol
January 2025
Department of Pediatrics, Children's Healthcare of Atlanta, Atlanta, GA, United States.
Background: Pediatric low-grade gliomas (pLGGs) have an overall survival of over 90%; however, patients harboring a BRAF alteration may have worse outcomes, particularly when treated with classic chemotherapy. Combined BRAF/MEK inhibition following incomplete resection demonstrated improved outcome in BRAF altered pLGG compared to combined carboplatin/vincristine chemotherapy and is now considered the standard FDA-approved treatment for this group of tumors. The aim herein was to investigate the efficacy and tolerability of single agent BRAF inhibitor treatment in BRAF altered pLGG.
View Article and Find Full Text PDFSpine Deform
January 2025
Department of Orthopaedics, NYU Langone Orthopedic Hospital, New York, NY, USA.
Purpose: Clinical trials have studied the effects of curve magnitude and flexibility, age, and skeletal immaturity on the outcomes of VBT. No studies have assessed the effect of Lenke curve type on the outcomes of VBT. This study compares outcomes in patients who underwent VBT with Lenke type 1, 3, 5, and 6 curves.
View Article and Find Full Text PDFBackground And Aims: Bendopnea is a symptom found in patients with heart failure (HF) defined as shortness of breath when bending forward. The present study examined the correlation between bendopnea with other cardiac symptoms, echocardiographic findings, and cardiac function parameters.
Methods: This was a single-center prospective cross-sectional study of patients diagnosed with systolic HF.
Shoulder Elbow
January 2025
IU Health Physicians Orthopedics & Sports Medicine, Indianapolis, IN, USA.
Purpose: The purpose of this study is to assess the long-term clinical complications, outcomes, and return to sport (RTS) rates in patients aged 30 or younger with a primary full-thickness arthroscopic rotator cuff repair (ARCR).
Methods: All patients who underwent a primary full-thickness ARCR at age 30 years or younger from 2003 to 2021 with a minimum of a 2-year follow-up were included. Complications, repeat surgeries, and return to sport rates were collected.
Cureus
December 2024
Department of Medical Oncology, Ankara Bilkent City Hospital, Ankara, TUR.
Introduction: In recent years, machine learning (ML) methods have gained significant popularity among medical researchers interested in cancer. We aimed to test different (ML) models to predict both overall survival and survival at specific time points in patients with non-metastatic colorectal cancer (CRC).
Methods: The clinicopathological and treatment data of non-metastatic CRC patients with more than 10 years of follow-up at a single center were retrospectively reviewed.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!