Incisor malocclusions are common in horses. As yet, an evidence-based understanding of incisor occlusal surface angle dynamics and normocclusal range is missing. Orthodontic measuring devices could help unravel this information objectively but imply measurement validation. We evaluated intra- and interexaminer variability of repeated sagittal and transversal incisor occlusal surface angle measures using a commercial orthodontic gauge device (). Five examiners (two experienced, three inexperienced) measured six cadaver heads on 2 consecutive days in a blinded block-randomization design, resulting in 16 measures per examiner*head. Sagittal and transversal angle measures revealed low intraexaminer variability at scale-level independent mean SDs of α 0.58° and α 0.69°, respectively. Sagittal angle measures associate with low interexaminer variability, showing small mean angle differences (max. α 0.51° ± 0.35°), small scatter, and more consistent data reproducibility. Despite comparable mean interexaminer differences, the spread of transversal angle measures was relevantly higher using the proposed landmarks (average 2.2-fold higher interquartile range). The measurement performance of experienced and inexperienced examiners did not systematically differ. The time required for individual measurements was already comparable after 24/96 repetitions. This instrument may help deciphering sagittal angle normocclusal range and orthognathic dynamics and, with a proposed procedural amendment, transversal angle as well.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9506125PMC
http://dx.doi.org/10.3390/vetsci9090481DOI Listing

Publication Analysis

Top Keywords

angle measures
16
incisor occlusal
12
occlusal surface
12
transversal angle
12
intra- interexaminer
8
orthodontic gauge
8
gauge device
8
angle
8
surface angle
8
normocclusal range
8

Similar Publications

Background: Pes planus (flatfoot) and pes cavus (high arch foot) are common foot deformities, often requiring clinical and radiographic assessment for diagnosis and potential subsequent management. Traditional diagnostic methods, while effective, pose limitations such as cost, radiation exposure, and accessibility, particularly in underserved areas.

Aim: To develop deep learning algorithms that detect and classify such deformities using smartphone cameras.

View Article and Find Full Text PDF

The transition from insulator to electro-responsive has been successfully achieved by earlier studies for some inorganic materials by applying external stimuli that modify their 3D and/or electronic structures. In the case of insulating polymers, this transition is frequently accomplished by mixing them with other electroactive materials, even though a few physical treatments that induce suitable chemical modifications have also been reported. In this work, a smart approach based on the application of an electro-thermal reorientation process followed by a charged gas activation treatment has been developed for transforming insulating 3D printed polymers into electro-responsive materials.

View Article and Find Full Text PDF

Fractal analysis of jawbone structure in patients with rheumatoid arthritis.

Imaging Sci Dent

December 2024

Department of Biostatistics and Medical Informatics, Faculty of Medicine, Suleyman Demirel University, Isparta, Turkey.

Purpose: Periarticular and generalized osteoporosis are well-known comorbidities of rheumatoid arthritis (RA), associated with either the disease itself or glucocorticoid therapy. This study was performed to quantitatively evaluate changes in the jawbones of patients with RA using fractal analysis (FA).

Materials And Methods: The study comprised 186 participants, including 144 women and 42 men.

View Article and Find Full Text PDF

Drones play a key role in enhancing nutrient management efficiency under climate change scenarios by enabling precise and adaptable spray applications. Current aerial spray application research is primarily focused on examining the influence of drone spraying parameters flight height, travel speed, rotor configuration, droplet size, payload, spray pressure, spray discharge and wind velocity on spray droplet deposition characteristics. The present study aimed to study and optimize the effect of spray height, operating pressure, nozzle spacing and spray nozzle mounting configuration on spray discharge rate, spray width, spray distribution pattern, spray uniformity and spray liquid loss.

View Article and Find Full Text PDF

Background: Studies have revealed abnormalities of the epiphyseal plate of the distal femur in patients with trochlear dysplasia, but it is unclear whether the epiphyseal plate could be remodeled after surgical correction of patellar dislocation.

Purpose: To investigate whether the morphology of the epiphyseal plate and trochlea could be improved after medial patellar retinaculum plasty in skeletally immature patients and to investigate the correlations between the morphology of the epiphyseal plate and trochlear dysplasia as well as clinical outcomes.

Study Design: Cohort study; Level of evidence, 3.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!