This study aimed to examine the differences in healing patterns using two types of diode laser devices (laser A and laser B) and a steel scalpel for periodontal surgery through histological and immunohistochemical methods. Twenty 12-week-old male rats were assigned to three groups (3, 7, and 14 days). Square-shaped erosion wounds (2 × 2 mm2 diameter) were created on the hard palate of each rat. Two wounds were created using Laser A and a steel scalpel (Bard-Parker No. 15) on the right palate and using Laser B and a steel scalpel on the left side. Rats were sacrificed after 3, 7, and 14 days. Tissues were collected with a margin of 1 mm from the border of the erosional wound of the maxillary hard palate. Histological and immunohistochemical analyses were performed on the tissue samples after 3, 7, and 14 days. The tissue healing pattern and expression of inducible nitric oxide synthase (iNOS) and cluster of differentiation (CD) were observed under a light microscope. Statistical analysis was conducted using the Kruskal−Wallis H test for comparison among the groups (α = 0.05). In comparison to the wounds made with the scalpel, wounds treated with lasers A and B showed delayed healing patterns. There was no significant difference between the two laser treatment groups (p > 0.05). The expression of iNOS and CD68 was not significantly different among the three groups after 3 and 7 days (p > 0.05). On day 14, the groups treated with the dental diode lasers showed higher expression than the group treated with the steel scalpel, but no significant difference was observed (p > 0.05). Laser-induced wounds tended to heal slower than surgical wounds performed using a steel scalpel, but histological and immunohistochemical results showed no significant difference between the dental diode laser and scalpel groups.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9495772PMC
http://dx.doi.org/10.3390/bioengineering9090466DOI Listing

Publication Analysis

Top Keywords

steel scalpel
20
dental diode
12
diode laser
12
laser steel
12
histological immunohistochemical
12
laser
8
laser treatment
8
healing patterns
8
three groups
8
groups days
8

Similar Publications

Cold atmospheric plasma devices generate reactive oxygen and nitrogen species that can be anti-microbial but also promote cell migration, differentiation, and tissue wound healing. This report investigates the healing of surgical incisions created using cold plasma generated by the J-Plasma scalpel (Precise Open handpiece, Apyx Medical, Inc.) compared to a steel scalpel in in vivo porcine and rat models.

View Article and Find Full Text PDF
Article Synopsis
  • - The ultrasonic deep-plane neck lift combines advanced surgical techniques and high-frequency ultrasound to effectively target and emulsify fat layers in both superficial and deep planes, enhancing facial rejuvenation outcomes.
  • - This procedure enables more precise surgery with less bleeding and eliminates the need for traditional cutting tools, while also addressing challenging areas like the perioral region and distal neck.
  • - Long-term benefits include continued tissue tightening and remodeling for up to a year following the surgery, marking a significant advancement in facelift surgery through the integration of innovative technology and years of research.
View Article and Find Full Text PDF

Tonsillectomy is one of the most common ear, nose and throat surgical procedure, carried out worldwide. Amongst the various method of tonsillectomy (diathermy, laser, harmonic scalpel, radiofrequency cautery cryosurgery and coblation), dissection and snare method is commonest procedure done by otorhinolaryngologist. To compare the post operative complications associated with coblation versus conventional cold-dissection steel tonsillectomy.

View Article and Find Full Text PDF

Introduction: Electrocautery is used widely in surgical procedures, but making skin incision has routinely been performed with scalpel rather than electrocautery, for fear that electrocautery may cause poor incision healing, excessive scarring and increased wound complication rates. More and more studies on general surgery support the use of electrocautery for skin incision, but research comparing the two modalities for scalp incision in neurosurgery remains inadequate. This trial aims to evaluate the safety and efficacy of needle-tip monopolar for scalp incision in supratentorial neurosurgery compared with steel scalpel.

View Article and Find Full Text PDF

Background: Due to the sensitivity of the surgical site and a higher probability of injury, the use of a scalpel and electrocautery to create an incision in the spine is discussed. In this study, we will compare the intraoperative and postoperative complications of the scalpel and electrocautery techniques for severing the inner layers of the lumbar disc during discectomy surgery.

Materials And Methods: This study was conducted in Iran as a randomized controlled trial with double-blinding (1,401).