Adhesion robots have broad application prospects in the field of spacecraft inspection, repair, and maintenance, but the stable adhesion and climbing on the flexible surface covering the spacecraft has not been achieved. The flexible surface is easily deformed when subjected to external force, which makes it difficult to ensure a sufficient contact area and then detach from it. To achieve stable attachment and easy detachment on the flexible surface under microgravity, an adhesion model is established based on the applied adhesive material, and the relationship between peeling force and the rigidity of the base material, peeling angle, and working surface stiffness is obtained. Combined with the characteristics of variable stiffness structure, the adhesion and detachment force of the foot is asymmetric. Inspired by the adhesion-detachment mechanism of the foot of the gecko, an active adhesion-detachment control compliant mechanism is designed to achieve the stable attachment and safe detachment of the foot on the flexible surface and to adapt to surfaces with different rigidity. The experimental results indicate that a maximum normal adhesion force of 7.66 N can be generated when fully extended, and the safe detachment is achieved without external force on a flexible surface. Finally, an air floating platform is used to build a microgravity environment, and the crawling experiment of a gecko-inspired robot on a flexible surface under microgravity is completed. The experimental results show that the gecko-inspired foot with variable stiffness can satisfy the requirements of stable crawling on flexible surfaces.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9496031 | PMC |
http://dx.doi.org/10.3390/biomimetics7030125 | DOI Listing |
Cureus
December 2024
Medical Affairs, Dr. Reddy's Laboratories Ltd., Hyderabad, IND.
Background Toothbrush manufacturers commonly use bristle materials such as nylon, polybutylene terephthalate, polypropylene, polyethylene terephthalate, boar hair, bamboo, carbon fiber, silicone, polylactic acid, or their modifications such as Curen. Nylon filaments have long been demonstrated to be durable and are widely used, but not much is known regarding the performance of Curen filaments compared to nylon filaments. This in vitro study compared the stiffness, abrasion potential, abrasion resistance, and bristle surface changes of Curen and nylon filaments.
View Article and Find Full Text PDFInt J Biol Macromol
January 2025
MOE Key Laboratory of Bio-Intelligent Manufacturing, Liaoning Key Laboratory of Molecular Recognition and Imaging, School of Bioengineering, Dalian University of Technology, Dalian 116023, PR China. Electronic address:
Surfaces capable of specific biomolecule recognition are essential for cancer theranostics, biosensing, and tissue engineering. However, current grafting methods, critical for dictating the recognition efficiency and biocompatibility of biomaterials, especially hydrophilic polymers, struggle to balance high grafting density with ease of implementation. In pursuit of a simple, effective, and versatile solution, we introduced a polydopamine (PDA)-assisted Ca-mediated grafting strategy using hyaluronic acid (HA) as a model material.
View Article and Find Full Text PDFMol Biotechnol
January 2025
Enzyme and Microbial Research Center, Faculty of Biotechnology and Biomolecular Sciences, Universiti Putra Malaysia, 43400, Serdang, Selangor, Malaysia.
Glucanases are widely applied in industrial applications such as brewing, biomass conversion, food, and animal feed. Glucanases catalyze the hydrolysis of glucan to produce the sugar hemiacetal through hydrolytic cleavage of glycosidic bonds. Current study aimed to investigate structural insights of a glucanase from Clostridium perfringens through blind molecular docking, site-specific molecular docking, molecular dynamics (MD) simulation, and binding energy calculation.
View Article and Find Full Text PDFSoft Matter
January 2025
Department of Chemistry, Columbia University, 3000 Broadway, New York, NY 10027, USA.
A remarkable property of flexible self-avoiding elastic surfaces (membranes) is that they remain flat at all temperatures, even in the absence of a bending rigidity or in the presence of active fluctuations. Here, we report numerical results of these surfaces wherein we alter their topology by systematically cleaving internal bonds. While it is known that a random removal of membrane bonds does not disrupt the overall extended shape of the membrane, we find that cleaving an elastic surface with longitudinal parallel cuts leads to its systematic collapse into a number of complex morphologies that can be controlled by altering the number and length of the inserted cuts.
View Article and Find Full Text PDFSmall
January 2025
College of Osteopathic Medicine, Liberty University, Lynchburg, VA, 24502, USA.
Using a combined top-down (i.e., operator-directed) and bottom-up (i.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!