Background: The use of intraoperative fluoroscopy (IF) is common with direct anterior total hip arthroplasty (THA), however image distortion in IF may limit its usefulness. The supplementation of IF with an adjustable grid (AG) may provide consistently better accuracy in component placement. Therefore, the purpose of this study was to compare the accuracy, consistency, and surgical efficiency between IF only and AG supplementation.
Methods: 2 cohorts were retrospectively evaluated, including 573 IF only patients and 211 AG patients having undergone unilateral THA between 2011 and 2018. Post-THA radiographic assessment was performed to evaluate the accuracy of component placement, with target placements for global hip offset (GHO) and leg-length differences (LLD) <10 mm and acetabular cup abduction of 45° (±10°). Accuracy and surgical efficiency were evaluated between groups and over time.
Results: The AG group had a significant greater percentage of components placed within the target zone compared to IF only for GHO (99.5%, 92.7%, < 0.001), LLD (99.1%, 96.5%, = 0.039) and abduction (99.5%, 96.3%, = 0.009), with no difference in fluoroscopic time ( = 0.973). Over time, accuracy was significantly different in IF group for GHO ( = 0.008) and abduction ( = 0.002) and trended toward significance for LLD ( = 0.055). There were no significant differences over time for the AG group.
Conclusions: The addition of an AG to IF significantly increased the accuracy of component placement during direct anterior THA. These results were consistent over 2 years of use and did not decrease surgical efficiency.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/11207000221089274 | DOI Listing |
J Occup Environ Hyg
January 2025
Department of Kinesiology & Health Promotion, University of Kentucky, Lexington, Kentucky.
Farmers may be at a higher risk of developing hip osteoarthritis (OA) due to the high demands of their occupation. To the authors' knowledge, the gait patterns of farmers that may be associated with hip joint degeneration have yet to be analyzed. Therefore, this study compares gait mechanics between farmers and non-farmers (controls).
View Article and Find Full Text PDFCalcif Tissue Int
January 2025
Internal Medicine Division, Federal University of Parana (UFPR), Curitiba, PR, Brazil.
Patients with radiographic axial spondyloarthritis (r-axSpA) experience a higher prevalence of fragility fractures, though the pathophysiology of osteoporosis associated with this disease remains poorly understood. The objective of this study was to evaluate the histomorphometric data in r-axSpA patients. Male r-axSpA patients up to 55 years old were enrolled in this cross-sectional study.
View Article and Find Full Text PDFKnee Surg Sports Traumatol Arthrosc
January 2025
Hospital Parc Taulí, Imove Traumatología, Barcelona, Spain.
Purpose: Studies evaluating the long-term survival rate, patient satisfaction, and conversion to total hip arthroplasty (THA) are limited. The aim of this study was to evaluate satisfaction and hip survival at a minimum 10-year follow-up in patients following hip arthroscopy for femoroacetabular impingement syndrome (FAIS).
Methods: A total of 164 patients underwent hip arthroscopy for FAIS between 2007 and 2012; of these, 76 (49 men and 27 women; mean age, 40.
Mol Med Rep
March 2025
Department of Orthopedics, People's Hospital of Zhengzhou University, Zhengzhou, Henan 450003, P.R. China.
Aseptic loosening (AL) of artificial hip joints is the most common complication following hip replacement surgery. A total of eight patients diagnosed with AL following total hip arthroplasty (THA) undergoing total hip replacement and eight control patients diagnosed with avascular necrosis of femoral head (ANFH) or femoral neck fracture undergoing THA were enrolled. The samples of the AL group were from synovial tissue surrounding the lining/head/neck of the prosthesis, and the samples of the control group were from the synovium in the joint cavity.
View Article and Find Full Text PDFSleep Epidemiol
December 2024
Department of Chronic Disease Epidemiology, Yale University School of Public Health, New Haven, CT, USA.
Sleep apnea is a global public health concern, but little research has examined this issue in low- and middle-income countries, including Samoa. The purpose of this study was to examine the sample prevalence and characteristics of sleep apnea using a validated home sleep apnea device (WatchPAT, Itamar) and explore factors that may influence sleep health in the Samoan setting. This study used data collected through the ("Good Health") study, which investigated the impact of the body mass index (BMI)-associated genetic variant rs373863828 in on metabolic traits in Samoan adults (sampled to overrepresent the obesity-risk allele of interest).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!