A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Monitoring and Identifying Insulin-Like Growth Factor 1 Variants by Liquid Chromatography-High-Resolution Mass Spectrometry in a Clinical Laboratory. | LitMetric

Protein and peptide hormones often exist as sequence variants with different molecular mass. Monitoring these variants of different molecular mass by mass spectrometry using mass-to-charge (m/z) ratio that is indicative of the wild type may lead to inaccurate quantitative results. However, liquid chromatography-high-resolution mass spectrometry (LC-HRMS)-based techniques can capture these differences and provide an opportunity to resolve, or partially resolve, variant complexity. In this chapter, we describe a general approach for monitoring a set of peptide variants with similar m/z ratios and isotopic envelopes, but different in amino acid sequences. As an example, we use insulin-like growth factor-1 (IGF-1) to demonstrate a DNA database-guided approach to monitor protein variants by LC-HRMS in a clinical laboratory. The workflow is automated and therefore avoids manual calculations that are prone to human error. The method can also monitor multiple IGF-1 variants and discover new ones. It can also provide a profile of a patient's IGF-1 status and be used to explore genotype-phenotype relationships in IGF-1 variants.

Download full-text PDF

Source
http://dx.doi.org/10.1007/978-1-0716-2565-1_22DOI Listing

Publication Analysis

Top Keywords

mass spectrometry
12
insulin-like growth
8
liquid chromatography-high-resolution
8
chromatography-high-resolution mass
8
clinical laboratory
8
variants molecular
8
molecular mass
8
igf-1 variants
8
variants
7
mass
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!