Objective: The purpose of this study was to examine the effect of insertion angles on the pullout strength of connected pins using a synthetic model simulating a hand bone.
Material And Methods: The material consisted of Sawbones® (20 mm×20 mm × 60 mm), fixation pins secured to a connecting rod much like an external fixator, an electric drill (speed 1,290 rpm) and a tensile testing machine. The Sawbones® were drilled with different pin diameters (1.2 mm, 1.5 mm, and 1.8 mm) and insertion angles (100°, 110° and 120°). A vertical displacement of 1 mm/min was applied until the pins were extracted (maximum force).
Results: The pullout strength increased with the insertion angle of the connected pins. It also increased with their diameter. Regardless of the pin diameter, the load-displacement curve during the pullout test had 4 sections (peak 1, ascending slope, peak 2, descending slope) that corresponded to the combined frictional force and contact force between the pins and Sawbones®.
Discussion: Our study findings showed that, theoretically, for wrist or hand fractures treated with connected pins, the larger the diameter and insertion angle, the better the mechanical holding power of the pins.
Level Of Evidence: I, experimental study.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.otsr.2022.103411 | DOI Listing |
OTA Int
March 2025
Department of Orthopedic Surgery, Detroit Medical Center, Detroit, MI.
Introduction: Intramedullary femoral nails (IMFNs) need to be removed for subsequent joint replacement, refracture, nonunion, or infection. The tools used to extract newer IMFNs may not be suited for removal of older implants, especially if broken. The purpose of this study was to describe a novel technique in femoral nail extraction when primary measures fail and a report on 6 cases where it was used.
View Article and Find Full Text PDFMaterials (Basel)
November 2024
State Key Laboratory of Mechanics and Control for Aerospace Structures, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China.
Emergency breakaway pins (EBPs) have been widely used in aircraft, especially in the suspension connection between the engine device and the airfoil. Currently, the existing EBPs, which are made of metal materials, barely satisfy the lightweight requirement of the airplane industry. Thus, the construction of a novel EBP with quartz fiber reinforced phenolics is proposed in this study, and the shear response is examined experimentally using a double-sided shear test.
View Article and Find Full Text PDFPLoS One
November 2024
Faculty of Mechanical Engineering and Marine Technology, Chair of Lightweight Design, University of Rostock, Rostock, Germany.
Introduction: Subtalar joint arthrodesis is primarily indicated for advanced osteoarthritis, hindfoot deformity, and/or instability. During the first 6-10 weeks after surgery, there is an intermediary structurally weaker state before complete bony fusion of the calcaneus and talus occurs. Loading of the foot can lead to mechanical stresses and relative movements in the former joint gap, which can impede the fusion process.
View Article and Find Full Text PDFUnited European Gastroenterol J
December 2024
Department of Gastroenterology, Hospital General de Tomelloso, Tomelloso, Spain.
Background: Eosinophilic esophagitis (EoE) predominantly affects males across all ages; however, little is known about sex differences for other aspects of EoE.
Objective: To investigate associations between sex and clinical presentation, endoscopic features, treatment choice and response in EoE patients in real-world practice.
Methods: Cross-sectional analysis of the multicenter EoE CONNECT registry.
JBJS Case Connect
July 2024
Department of Orthopaedic Surgery, University of California, San Francisco, California.
Case: A 34-year-old man with a distal tibia bone defect was treated with an intramedullary bone transport nail (Precice Bone Transport System, NuVasive). During planned removal after successful treatment, 7 separate subcomponents of the nail became disconnected and had to be separately removed using specialized instrumentation. This occurred despite adherence to the manufacturer's recommended technique for nail removal and in the absence of clinical or radiographic evidence of implant failure.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!