A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Control of the surface profile of powder using the flexural vibration of a V-shaped plate. | LitMetric

Control of the surface profile of powder using the flexural vibration of a V-shaped plate.

Ultrasonics

Faculty of Science and Engineering, Doshisha University, 1-3 Tataramiyakodani, Kyotanabe, Kyoto 610-0321, Japan. Electronic address:

Published: January 2023

In the pharmaceutical field, a technique to level the surface of powdered medicines is important in the dispensing process because the flatness of the powder surface affects the packaging accuracy directly. This paper investigates a method for leveling of the surface profile of powder using ultrasound vibration on a plate. The system used comprises a V-shaped plate and two ultrasound transducers, and the plate configuration required was determined from the results of simulations performed by finite element analysis. The resonant longitudinal vibration of the transducers generated the resonant flexural vibration mode of the plate at 27.4 kHz, which resulted in transportation and leveling of the powder. The powder was aggregated at the nodal positions of the flexural standing wave, and a correlation was observed between the sound pressure distribution over the plate and the surface profile of the powder. The powder leveling accuracy was investigated by varying the driving phase difference between the transducers, and it was found that a smaller standing wave ratio for the flexural vibration produced higher leveling accuracy. When the input voltage to the transducers was increased, the leveling time decreased and the leveling accuracy improved; the highest leveling accuracy obtained was 2.2 mm at 130 V.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultras.2022.106848DOI Listing

Publication Analysis

Top Keywords

leveling accuracy
16
surface profile
12
profile powder
12
flexural vibration
12
v-shaped plate
8
powder powder
8
standing wave
8
powder
7
leveling
7
plate
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!