The outbreak of COVID-19, beginning in 2019 and continuing through the time of writing, has led to renewed interest in the mathematical modeling of infectious disease. Recent works have focused on partial differential equation (PDE) models, particularly reaction-diffusion models, able to describe the progression of an epidemic in both space and time. These studies have shown generally promising results in describing and predicting COVID-19 progression. However, people often travel long distances in short periods of time, leading to nonlocal transmission of the disease. Such contagion dynamics are not well-represented by diffusion alone. In contrast, ordinary differential equation (ODE) models may easily account for this behavior by considering disparate regions as nodes in a network, with the edges defining nonlocal transmission. In this work, we attempt to combine these modeling paradigms via the introduction of a network structure within a reaction-diffusion PDE system. This is achieved through the definition of a population-transfer operator, which couples disjoint and potentially distant geographic regions, facilitating nonlocal population movement between them. We provide analytical results demonstrating that this operator does not disrupt the physical consistency or mathematical well-posedness of the system, and verify these results through numerical experiments. We then use this technique to simulate the COVID-19 epidemic in the Brazilian region of Rio de Janeiro, showcasing its ability to capture important nonlocal behaviors, while maintaining the advantages of a reaction-diffusion model for describing local dynamics.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9475403PMC
http://dx.doi.org/10.1016/j.cma.2022.115541DOI Listing

Publication Analysis

Top Keywords

population movement
8
differential equation
8
nonlocal transmission
8
modeling nonlocal
4
nonlocal behavior
4
behavior epidemics
4
reaction-diffusion
4
epidemics reaction-diffusion
4
reaction-diffusion system
4
system incorporating
4

Similar Publications

Background: This study investigated the effect of various offloading devices commonly used for the management of diabetic foot ulcerations on peak plantar pressure and pressure-time integral of the contralateral limb.

Methods: A quantitative, randomised and within-subject repeated measures study was conducted in an outpatient gait laboratory. Outpatients with unilateral diabetic foot ulcers and adequate perfusion to the lower limb without an intrinsic limb-length discrepancy who were able to walk were recruited for the study.

View Article and Find Full Text PDF

Validation of the OPTIMAL-Confidence Questionnaire in Patients with Chronic Low Back Pain.

J Clin Med

January 2025

SALBIS Research Group, Department of Nursing and Physical Therapy, Faculty of Health Sciences, Campus de Ponferrada, Universidad de León, 24401 Ponferrada, Spain.

Unlabelled: Low back pain is one of the most prevalent pathologies. Several studies relate its chronification to certain psycho-emotional characteristics, such as self-efficacy or the patient's lack of confidence in the ability to move. Determine the reliability and validity of the OPTIMAL-confidence scale in people with chronic low back pain and describe the confidence in the movement capacity of this population.

View Article and Find Full Text PDF

Involutional lower eyelid ectropion is a common disorder of the elderly population. Several surgical approaches have been described in the literature to address the multifactorial nature of this condition, each targeting different factors contributing to its development. Nevertheless, no single procedure has proven to be superior to the others.

View Article and Find Full Text PDF

Validation of Aerobic Capacity (VO2max) and Pulse Oximetry in Wearable Technology.

Sensors (Basel)

January 2025

School of Integrated Health Sciences, Department of Kinesiology and Nutrition Sciences, University of Nevada, Las Vegas, NV 89154, USA.

Introduction: As wearable technology becomes increasingly popular and sophisticated, independent validation is needed to determine its accuracy and potential applications. Therefore, the purpose of this study was to evaluate the accuracy (validity) of VO2max estimates and blood oxygen saturation measured via pulse oximetry using the Garmin fēnix 6 with a general population participant pool.

Methods: We recruited apparently healthy individuals (both active and sedentary) for VO2max (n = 19) and pulse oximetry testing (n = 22).

View Article and Find Full Text PDF

Continuous glucose monitoring (CGM) might provide immediate feedback regarding lifestyle choices such as diet and physical activity (PA). The impact of dietary habits and physical activity can be demonstrated in real time by providing continuous data on glucose levels and enhancing patient engagement and adherence to lifestyle modifications. Originally developed for diabetic patients, its use has recently been extended to a non-diabetic population to improve cardiovascular health.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!