Background: In January 2019, a new device called the Amplatzer Piccolo Occluder was approved by the US Food and Drug Administration for percutaneous closure of patent ductus arteriosus in infants weighing more than 700 g and of postnatal age more than 3 days. Premature low-weight infants are predisposed to hypothermia when transported outside of the thermo-neutral environment. At our institution, 90% of extremely preterm low-weight infants developed transient moderate hypothermia in the cardiac catheterisation suite.
Methods: We conducted a study testing multiple hypotheses aimed at preventing hypothermia in the cardiac catheterisation suite. Interventions included increasing ambient room temperature, reducing exposure to cold environment and reducing overall time spent in the remote location. The primary outcome was the proportion of patients who developed transient hypothermia at the start of the procedure in the cardiac catheterisation suite. The secondary measures included mean core body temperature at four different instances, as well as anaesthesia time, procedure time and radiation exposure.
Results: During the study period, 10 patients were enrolled in each group. The postintervention group saw a reduction in transient hypothermia from 90% to 40% (absolute risk reduction 50%, p=0.02). Data analysis showed an improvement in mean core body temperature (35.4°C vs 36.4°C, p<0.01) as well as a smaller percentage drop in temperature (4% vs 1.3%, p<0.01) between the two groups, both of which were statistically significant. The anaesthesia time, procedure time and radiation exposure reduced between the two groups.
Conclusion: The application of the interventions reduced hypothermia in this high-risk population. The implementation of a protocol with collaboration of a multidisciplinary team is indispensable in providing optimal care to extremely preterm infants.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9486285 | PMC |
http://dx.doi.org/10.1136/bmjoq-2021-001773 | DOI Listing |
J Nucl Med
January 2025
Department of Pulmonary and Critical Care Medicine, First Affiliated Hospital of Guangzhou Medical University, Guangzhou Institute of Respiratory Health, State Key Laboratory of Respiratory Disease, National Clinical Research Center for Respiratory Disease, Guangzhou, China; and
The purpose of this study was to investigate the feasibility of using F-labeled fibroblast activation protein inhibitor (FAPI) PET/CT in assessing the fibrotic remodeling of the pulmonary artery (PA) and the right ventricle (RV) in pulmonary arterial hypertension (PAH). In a rat model of monocrotaline-induced PAH, rats were euthanized at different time points for tissue analysis (fibroblast activation protein immunofluorescence and Masson's trichrome staining) after completing F-FAPI PET/CT and hemodynamic measurements. Thirty-eight PAH patients were enrolled to participate in F-FAPI PET/CT imaging, with right heart catheterization and echocardiography performed within 1 wk to assess pulmonary hemodynamics and cardiac function.
View Article and Find Full Text PDFCirc Cardiovasc Qual Outcomes
January 2025
Scientific Publications Committee, American College of Cardiology, Washington, DC (J.A.B.).
BMC Pharmacol Toxicol
January 2025
Department of Pharmacy, Zhongshan Hospital, Fudan University, Shanghai, 200032, China.
The main objective of this study was to investigate the optimal post-left atrial appendage closure (LAAC) anticoagulation strategy, focusing on minimizing device-related thrombosis (DRT) and thromboembolism (TE) events without increasing bleeding risk. After successful LAAC, consecutive participants were treated with 45-day anticoagulants (rivaroxaban 15 mg daily, dabigatran 110 mg twice a day, and warfarin). The efficacy endpoints included DRT, TE, and hospital readmissions due to cardiac caused, while safety endpoints encompassed bleeding events, monitored over a 12-month follow-up period.
View Article and Find Full Text PDFCardiovasc Ultrasound
January 2025
Cardiology Department, Hospital de Santa Marta, Unidade Local de Saúde São José, Centro Clínico Académico de Lisboa, Rua de Santa Marta N.º 50, Lisbon, 1169-024, Portugal.
Background: Right ventricular myocardial work (RVMW) assessed by transthoracic echocardiography allows to study the right ventricular (RV) function using RV pressure-strain loops. The assessment of these novel indexes of RVMW has not yet been exten sively studied, namely in pre-capillary pulmonary hypertension (PH) population.
Objectives: to evaluate the relationship between RVMW and invasive indices of right heart catheterization (RHC) in a cohort of patients with group I and group IV PH and to compare with a control group without PH.
Am J Med
December 2024
University of Arizona, College of Medicine, Phoenix.
Background: Breast implants interfere with myocardial perfusion imaging (SPECT) and echocardiographic windows leading to increased false positive results. To validate this concept, we hypothesized that patients with breast implants should have higher positive cardiac testing and coronary angiogram with lower percutaneous coronary intervention (PCI) rates compared to women without a breast implant.
Methods: Using ICD 10 codes for breast implants, abnormal results of cardiac functional study, coronary angiogram, and percutaneous coronary interventions, we evaluated any association between these parameters in adult women with breast implants utilizing the National Inpatient Sample (NIS) database.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!