Objective: This study aims to evaluate the endoprosthesis complications in patients undergoing TEVAR for blunt traumatic thoracic aortic injury, through long-term clinical and diagnostic follow-up.
Methods: During the study interval (November 2000-October 2020), a total of 38 patients (63% male; average age 37.5 years) with thoracic aortic injury underwent thoracic endovascular aortic repair. Patients underwent routine follow-up with clinical examination and radiological evaluation (CT-angiography or MRI-angiography plus chest radiograph), scheduled at 1 month, at 6 months (only in the cases of thoracic aortic dissection), at 1 year after the procedure and every 1 year thereafter.
Results: Technical success was achieved in 38 procedures (100%). The TEVAR-related mortality rate was 0%. No immediate major complications related to the endovascular procedure were observed. The median duration of diagnostic follow-up was 80 months. A total of four procedure-related complications (10.5%) were identified at the follow-up. Three (7.9%) distal infoldings and collapses of the thoracic endoprosthesis and one (2.6%) type Ia endoleak were observed. No thrombosis of the prosthesis, nor signs of aortic pseudocoarctation were identified. No further complications related to endograft (endoleaks, infections, rupture, partial or complete thrombosis) occurred. No changes in the native aorta, stenosis, or increases in the endograft's diameters were observed. A total of 20 patients (52.6%) underwent MRI-angiography examinations, while a total of 34 patients (89.5%) underwent chest radiographs at the follow-up. In all cases, CT-angiography examinations were performed at the follow-up.
Conclusions: Procedure-related complications were observed within one year of TEVAR, limiting concerns related to the durability of the prosthesis. No morphological changes in the aorta were observed despite long-term follow-up. The consequences of lifelong surveillance in terms of radiation exposure deserve special consideration, especially in younger patients treated for TAI.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/17085381221127740 | DOI Listing |
Int J Surg
January 2025
Department of Cardio-Thoracic Surgery, Nanjing Drum Tower Hospital, Chinese Academy of Medical Science & Peking Union Medical College, Nanjing, Jiangsu, China.
Background: Type A aortic dissection (TAAD) remains a significant challenge in cardiac surgery, presenting high risks of adverse outcomes such as permanent neurological dysfunction and mortality despite advances in medical technology and surgical techniques. This study investigates the use of quantitative electroencephalography (QEEG) to monitor and predict neurological outcomes during the perioperative period in TAAD patients.
Methods: This prospective observational study was conducted at the hospital, involving patients undergoing TAAD surgery from February 2022 to January 2023.
Int J Surg
January 2025
Department of Cardiovascular Surgery, Nanchong Central Hospital, The Affiliated Nanchong Central Hospital of North Sichuan Medical College, Nanchong Hospital of Beijing Anzhen Hospital Capital Medical University, Nanchong, China.
Objective: This systematic review and meta-analysis aimed to evaluate and compare the efficacy of endovascular versus open repair for the treatment of patients with descending thoracic aortic aneurysm (DTAA).
Methods: A systematic search of the PubMed, Embase, and Cochrane Library databases for relevant studies was performed. Outcome data, including postoperative mortality and morbidity, operative details, all-cause survival, freedom from aortic-related survival and freedom from aortic-related re-intervention, were independently extracted by two authors in a standardized way.
Catheter Cardiovasc Interv
January 2025
Department of Cardiology, Istanbul Mehmet Akif Ersoy Thoracic and Cardiovascular Surgery Training and Research Hospital, Istanbul, Turkey.
Background: Access-related vascular complications (VCs) after percutaneous transfemoral transcatheter aortic valve replacement (TAVR) are associated with poor clinical outcomes and remain a significant challenge despite technological advances. The aim of this study was to identify anatomic predictors of access-related VCs after TAVR on preprocedural contrast-enhanced multidetector computed tomography (MDCT).
Aims: The aim of this study was to identify anatomical predictors of access-related VCs after TAVR on preprocedural contrast-enhanced MDCT.
Radiol Case Rep
March 2025
Division of Maternal Fetal Medicine, Department of Obstetrics and Gynecology, State University of New York (SUNY), Downstate Health Sciences University, Brooklyn, NY, USA.
Extensive congenital pulmonary airway malformation (CPAM) of the left fetal lung and associated marked dextroposition of the fetal heart were noted at 21 weeks' gestation. The right fetal lung appeared compressed with the cardiomediastinal shift angle measuring approximately 20 degrees. Potential subsequent right pulmonary hypoplasia was considered.
View Article and Find Full Text PDFRadiol Case Rep
March 2025
Maimonides Medical Center, Brooklyn, NY, USA.
Thoracic aortic pseudoaneurysms are a rare but serious complication of infectious processes, often resulting from mycotic (infectious) aneurysms, occurring when the vessel wall is compromised by an infection, leading to the formation of a pseudoaneurysm [1]. Mycotic aneurysms typically result from bacteremia or fungemia, with common sources being infective endocarditis or other systemic infections. Tuberculosis, though a common infectious disease worldwide, is an unusual cause of aortic pseudoaneurysm formation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!