Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: The aim of the present study was to determine whether microperimetric parameters could predict the progression of an eye at high risk of age-related macular degeneration (AMD) at 24 months.
Methods: We conducted a multicentric prospective non-comparative open-label study including patients with one eye in stage 4 of the Age-Related Eye Disease Study Group (AREDS) classification, and the other eye in AREDS stage 3 (study eye). A microperimetry examination (MAIA™, CenterVue, Padova, Italy) was performed at baseline and every 6 months during the 2-year follow-up. At the end of the follow-up, each study eye was classified as 'progressive' (i.e. AREDS stage 4) or 'non-progressive' (i.e. AREDS stage 3).
Results: A total of 147 patients were analysed, of which 30.6% progressed from AREDS stage 3 to stage 4. The microperimetry criterion 'mean retinal sensitivity' was significantly different at baseline between non-progressive and progressive eyes (p = 0.022), with lower values for the latter. With a threshold for mean retinal sensitivity set at 24.7 dB, diagnostic sensitivity was 80% [95%CI (65.4-90.4)], specificity was 30.4% [95%CI (21.7-40.3)], positive predictive value was 33.6% [95%CI (24.8-43.4)], and negative predictive value was 77.5% [95%CI (61.5-89.2)]. In the multivariate analysis including microperimetric parameters and other routine ophthalmologic examinations, mean retinal sensitivity was the only predictive parameter statistically associated with progression (p = 0.0004).
Conclusions: Our findings are encouraging as regards the use of microperimetry, and mean retinal sensitivity value in particular, to predict the 2-year risk of progression to AREDS stage 4 eye.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/aos.15260 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!