Objective: During PCL reconstruction surgery, precise and personalized positioning of the graft tunnel is very important. In order to obtain patient-specific anatomical data, we established a three-dimensional knee joint fusion model to provide a unified imaging strategy, as well as anatomical information, for individualized and accurate posterior cruciate ligament (PCL) reconstruction.

Methods: This is an exploration study. From January 2019 to January 2020, 20 healthy adults randomly were enrolled and assessed via CT and MRI imaging. A three-dimensional fusion model of the knee joint was generated using the modified MIMIMICS and image fusion software. On the fused image, the areas of the femoral and tibial PCL footprint of both knees were measured. The anatomical center of the PCL footprint was measured at the femoral and tibial ends. The relevant bony landmarks surrounding the PCL femoral and tibial attachment were also measured. Paired t-tests were employed for all statistical analyzes, and p < 0.05 was considered as statistically significant.

Results: All 20 subjects achieved successful image fusion modeling and measurement, with an average duration of 12 h. The lengths of the LF1-LF3 were 32.1 ± 1.8, 6.8 ± 2.5, and 23.3 ± 2.1 mm, respectively. The lengths of the LT1-LT3 were 37.3 ± 3.3, 45.6 ± 5.3, and 6.0 ± 1.2 mm, respectively. The distances between the tibial PCL center of the left knee to the medial groove, champagne-glass drop-off, and the apex of the medial intercondylar were 8.4 ± 2.4, 9.2 ± 1.8, and 15.3 ± 1.4 mm, respectively, and the corresponding distances from the right knee were 8.0 ± 2.0, 9.4 ± 2.2, and 16.1 ± 1.8 mm, respectively. We observed no difference between the bilateral sides, in terms of the distance from the PCL center to the PCL attachment-related landmark, under arthroscopic guidance. The area of the femoral and tibial PCL footprints on the left knee were 115.3 ± 33.5 and 146.6 ± 24.4 mm , respectively, and the corresponding areas on the right knee were 121.8 ± 35.6 and 142.8 ± 19.5 mm , respectively. There was no difference between the bilateral sides in terms of the PCL footprint areas.

Conclusion: In the fusion image, the PCL attachment center and relevant bony landmarks which can be easily identified under arthroscopy can be accurately measured. The model can also obtain personalized anatomical data of the PCL on the unaffected side of the patient, which can guide clinical PCL reconstruction.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9627086PMC
http://dx.doi.org/10.1111/os.13477DOI Listing

Publication Analysis

Top Keywords

femoral tibial
12
posterior cruciate
8
cruciate ligament
8
knee joint
8
fusion model
8
pcl footprint
8
pcl
5
application ct-mri
4
ct-mri fusion-based
4
fusion-based three-dimensional
4

Similar Publications

Purpose: Previous studies have shown that subtrochanteric femoral fractures treated with intramedullary nails might lead to varus-procurvatum malalignment. Similar results have been reported when using antegrade intramedullary lengthening nails (ILNs). The purpose of our study is to examine if antegrade telescoping intramedullary lengthening nails lead to varus-procurvatum malalignment of the proximal femur and what are possible predictors of that shift.

View Article and Find Full Text PDF

Objective: The incidence of anterior cruciate ligament (ACL) ruptures has been increasing annually. However, clinical surgeons have overlooked the impaction fractures of the posterolateral tibial plateau and lateral femoral condyle in patients with ACL ruptures. The purpose of the present study was to report the detection rate of the posterolateral tibial plateau impaction fractures in patients with ACL ruptures, and to evaluate the functional outcomes of patients following ACL reconstruction (ACLR) without treatment of the tibial fractures at a 2-year postoperative follow-up.

View Article and Find Full Text PDF

In clinical movement biomechanics, kinematic measurements are collected to characterise the motion of articulating joints and investigate how different factors influence movement patterns. Representative time-series signals are calculated to encapsulate (complex and multidimensional) kinematic datasets succinctly. Exacerbated by numerous difficulties to consistently define joint coordinate frames, the influence of local frame orientation and position on the characteristics of the resultant kinematic signals has been previously proven to be a major limitation.

View Article and Find Full Text PDF

Case: A 75-year-old woman underwent cruciate retaining total knee arthroplasty (TKA) for osteonecrosis of the knee, converted from unicompartmental arthroplasty due to an intraoperative medial tibial plateau fracture. Four years later, she experienced persistent knee pain. Computed tomography revealed tibial malalignments in 2 planes.

View Article and Find Full Text PDF

Unlabelled: The increased rate of anterior cruciate ligament (ACL) tears has led to a greater number of revisions. Revision surgery can be performed in one or two stages. Single-stage revision ACL reconstruction (ssRACLR) may be performed when prior tunnels can be re-used or bypassed whereas a two-stage procedure is indicated when bone grafting of dilated tunnels prior to revision is necessary.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!