A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Pulse oximetry vs non-invasive blood pressure/oscillometry to record blood pressure in neonates: A prospective observational study. | LitMetric

Aim: To assess the usefulness and efficacy of pulse oximetry (disappearance/reappearance of plethsmographic waves) as a method of non-invasive blood pressure monitoring in neonates.

Objective: To investigate the reliability of the plethysmographic wave form of the pulse oximeter to measure the systolic blood pressure.

Study Setting: A prospective observational study was done to assess usefulness and efficacy of pulse oximetry (disappearance/reappearance of plethysmographic waves) as a method of non-invasive blood pressure monitoring in neonates.

Material And Methods: The study was conducted among 500 neonates to investigate the reliability of the plethysmographic waveform of the pulse oximeter to measure the systolic blood pressure as it is a easy way to perform and non invasive.

Statistical Analysis Used: The results will compare and analyse statistically by Pearson correlation co-efficient. Regression modeling will carried out to explain the relationship of non-invasive blood pressure with mean DP and RP and attempted to predict the non-invasive blood pressure from mean DP/mean RP.

Results: The study results revealed that NIBP systolic and diastolic both correlated with DP and RP of pulse oximetry plethysmograph.

Conclusion: Study concluded that pulse oximetry is a reliable tool in measuring blood pressure in neonates (appearance and disappearance of plethysmogram).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9480655PMC
http://dx.doi.org/10.4103/jfmpc.jfmpc_1381_21DOI Listing

Publication Analysis

Top Keywords

blood pressure
28
pulse oximetry
20
non-invasive blood
20
blood
9
pressure neonates
8
prospective observational
8
observational study
8
assess efficacy
8
efficacy pulse
8
oximetry disappearance/reappearance
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!