Asymmetric visual capture of virtual sound sources in the distance dimension.

Front Neurosci

Department of Otolaryngology and Communicative Disorders, Heuser Hearing Institute, University of Louisville, Louisville, KY, United States.

Published: September 2022

Visual capture describes the tendency of a sound to be mislocalized to the location of a plausible visual target. This effect, also known as the ventriloquist effect, has been extensively studied in humans, but primarily for mismatches in the angular direction between auditory and visual targets. Here, visual capture was examined in the distance dimension using a single visual target (an un-energized loudspeaker) and invisible virtual sound sources presented over headphones. The sound sources were synthesized from binaural impulse-response measurements at distances ranging from 1 to 5 m (0.25 m steps) in the semi-reverberant room (7.7 × 4.2 × 2.7 m) in which the experiment was conducted. Listeners ( = 11) were asked whether or not the auditory target appeared to be at the same distance as the visual target. Within a block of trials, the visual target was placed at a fixed distance of 1.5, 3, or 4.5 m, and the auditory target varied randomly from trial-to-trial over the sample of measurement distances. The resulting psychometric functions were generally consistent with visual capture in distance, but the capture was asymmetric: Sound sources behind the visual target were more strongly captured than sources in front of the visual target. This asymmetry is consistent with previous reports in the literature, and is shown here to be well predicted by a simple model of sensory integration and decision in which perceived auditory space is compressed logarithmically in distance and has lower resolution than perceived visual space.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9475063PMC
http://dx.doi.org/10.3389/fnins.2022.958577DOI Listing

Publication Analysis

Top Keywords

visual target
24
visual capture
16
sound sources
16
visual
11
virtual sound
8
distance dimension
8
target
8
auditory target
8
distance
6
capture
5

Similar Publications

Objective: Although the 5-level EQ-5D version (EQ-5D-5L) instrument has been used to determine health-related quality of life and health utility in gout, it is used in comparing health utility among gout flare (GF) and non-gout flare (non-GF) patients is still limited. This study aimed to compare health utility among GF and non-GF patients in Thailand.

Methods: In this multi-center cross-sectional study, patients with GF and non-GF were interviewed for the EQ-5D5L and EQ-Visual Analog Scale (VAS) instruments by rheumatologists or trained research staffs.

View Article and Find Full Text PDF

Purpose: Low-dose CT (LDCT) screening effectively reduces lung adenocarcinoma (LUAD) mortality. However, accurately evaluating the malignant potential of indeterminate lung nodules remains a challenge. Carcinoembryonic antigen cell adhesion molecule 6 (CEACAM6), a potential biomarker for distinguishing benign pulmonary nodules from LUAD, may be leveraged for noninvasive positron emission tomography (PET) imaging to aid LUAD diagnosis.

View Article and Find Full Text PDF

Antibiotic-resistant bacteria often cause lethal infections in both the surficial and deep organs of humans. Failure of antibiotics in resistant infections leads to more effective alternative therapies, like spatiotemporally controllable piezodynamic therapy (PZDT) with deep penetration. Currently, PZDT demands further investigation for improved treatment outcomes and the corresponding therapeutic mechanisms.

View Article and Find Full Text PDF

Photothermal-Responsive Soluble Microneedle Patches for Meibomian Gland Dysfunction Therapy.

Adv Sci (Weinh)

January 2025

Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Key Laboratory of Ophthalmology & Visual Sciences, Beijing, 100730, China.

Meibomian gland dysfunction (MGD) is a leading cause of evaporative dry eye disease, presenting a challenge for targeted treatment. Traditional topical ocular drug delivery methods often fail to effectively reach the meibomian glands (MGs). To address this, the study has developed a soluble microneedles (MN) patch comprising poly(vinyl alcohol), cyclodextrin modified polyacrylic acid, and new indocyanine green.

View Article and Find Full Text PDF

Integrating Humidity-Resistant and Colorimetric COF-on-MOF Sensors with Artificial Intelligence Assisted Data Analysis for Visualization of Volatile Organic Compounds Sensing.

Adv Sci (Weinh)

January 2025

National Research Center of Engineering and Technology for Utilization of Botanical Functional Ingredients, Hunan Agricultural University, Changsha, 410128, P. R. China.

Direct visualization and monitoring of volatile organic compounds (VOCs) sensing processes via portable colorimetric sensors are highly desired but challenging targets. The key challenge resides in the development of efficient sensing systems with high sensitivity, selectivity, humidity resistance, and profuse color change. Herein, a strategy is reported for the direct visualization of VOCs sensing by mimicking human olfactory function and integrating colorimetric COF-on-MOF sensors with artificial intelligence (AI)-assisted data analysis techniques.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!