The clinical effect of point-of-care HIV diagnosis in infants: a systematic review and meta-analysis.

Lancet

World Health Organization, Geneva, Switzerland. Electronic address:

Published: September 2022

Background: Timely diagnosis and treatment of HIV is crucial in HIV-exposed infants to prevent the high rates of mortality seen during the first 2 years of life if HIV is untreated. However, challenges with sample transportation, testing, and result delivery to caregivers have led to long delays in treatment initiation. We aimed to compare the clinical effect of point-of-care HIV testing versus laboratory-based testing (standard of care) in HIV-exposed infants.

Methods: We did a systematic review and meta-analysis and searched PubMed, MEDLINE, Cochrane Central Register of Controlled Trials, Embase, Conference Proceedings Citation Index-Science, and WHO Global Index Medicus, from Jan 1, 2014, to Aug 31, 2020. Studies were included if they pertained to the use of point-of-care nucleic acid testing for infant HIV diagnosis, had a laboratory-based nucleic acid test as the comparator or standard of care against the index test (same-day point-of-care testing), evaluated clinical outcomes when point-of-care testing was used, and included HIV-exposed infants aged younger than 2 years. Studies were excluded if they did not use a laboratory-based comparator, a nucleic acid test that had been approved by a stringent regulatory authority, or diagnostic-accuracy or performance evaluations (eg, no clinical outcomes included). Reviews, non-research letters, commentaries, and editorials were also excluded. The risk of bias was evaluated using the ROBINS-I framework. Data were extracted from published reports. Data from all studies were analysed using frequency statistics to describe the overall populations evaluated and their results. Key outcomes were time to result delivery and antiretroviral therapy initiation, and proportion of HIV-positive infants initiated on antiretroviral therapy within 60 days after sample collection.

Findings: 164 studies were identified by the search and seven were included in the analysis, comprising 37 377 infants in total across 15 countries, including 25 170 (67%) who had point-of-care HIV testing and 12 207 (33%) who had standard-of-care testing. The certainty of evidence was high. Same-day point-of-care testing led to a significantly shorter time between sample collection and result delivery to caregivers compared with standard-of-care testing (median 0 days [95% CI 0-0] vs 35 days [35-37]). Time from sample collection to antiretroviral therapy initiation in infants found to be HIV-positive was significantly lower with point-of-care testing compared with standard of care (median 0 days [95% CI 0-1] vs 40 days [36-44]). When each study's result was weighted equally, 90·3% (95% CI 76·7-96·5) of HIV-positive infants diagnosed using point-of-care testing had started antiretroviral therapy within 60 days of sample collection, compared with only 51·6% (27·1-75·7) who had standard-of-care testing (odds ratio 8·74 [95% CI 6·6-11·6]; p<0·0001).

Interpretation: Overall, the certainty of the evidence in this analysis was rated as high for the primary outcomes related to result delivery and treatment initiation, with no serious risk of bias, inconsistency, indirectness, or imprecision. In HIV-exposed infants, same-day point-of-care HIV testing was associated with significantly improved time to result delivery, time to antiretroviral therapy initiation, and proportion of HIV-positive infants starting antiretroviral therapy within 60 days compared with standard of care.

Funding: The Bill & Melinda Gates Foundation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/S0140-6736(22)01492-1DOI Listing

Publication Analysis

Top Keywords

point-of-care testing
20
antiretroviral therapy
16
testing
13
point-of-care hiv
12
result delivery
12
standard care
12
nucleic acid
12
standard-of-care testing
12
sample collection
12
clinical point-of-care
8

Similar Publications

Background: Respiratory viral infections are a major public health challenge and the most diagnosed medical condition, particularly for individuals living in close proximity, like military personnel. We compared the sensitivity and specificity of the Biomeme Franklin and Truelab RT-PCR thermocyclers to determine which platform is more sensitive and specific at detecting SARS-CoV-2 and influenza A and B viruses.

Methodology: RNA extracted from nasopharyngeal swabs of infected and uninfected individuals was tested on the Biomeme Franklin at Lackland and the Truelab at Wright Patterson Air Force bases.

View Article and Find Full Text PDF

Lock-in amplifiers (LIAs) are critical tools in precision measurement, particularly for applications involving weak signals obscured by noise. Advances in signal processing algorithms and hardware synthesis have enabled accurate signal extraction, even in extremely noisy environments, making LIAs indispensable in sensor applications for healthcare, industry, and other services. For instance, the electrical impedance measurement of the human body, organs, tissues, and cells, known as bioelectrical impedance, is commonly used in biomedical and healthcare applications because it is non-invasive and relatively inexpensive.

View Article and Find Full Text PDF

Reusable Biosensor for Easy RNA Detection from Unfiltered Saliva.

Sensors (Basel)

January 2025

Department of Clinical and Molecular Biochemistry, Pomeranian Medical University in Szczecin, 72 Powstańców Wlkp. Al., 70-111 Szczecin, Poland.

Biosensors are transforming point-of-care diagnostics by simplifying the detection process and enabling rapid, accurate testing. This study introduces a novel, reusable biosensor designed for direct viral RNA detection from unfiltered saliva, targeting SARS-CoV-2. Unlike conventional methods requiring filtration, our biosensor leverages a unique electrode design that prevents interference from saliva debris, allowing precise measurements.

View Article and Find Full Text PDF

Small intestinal bacterial overgrowth (SIBO) is a disorder characterized by the excessive growth of bacteria in the small intestine. Bacterial overgrowth disrupts the bacterial balance and can lead to abdominal pain, weight loss, and gastrointestinal symptoms, including bloating, diarrhea, and malabsorption. SIBO is widespread in the population.

View Article and Find Full Text PDF

A Robust Normally Closed Pneumatic Valve for Integrated Microfluidic Flow Control.

Micromachines (Basel)

December 2024

Zepto Life Technology Inc., 1000 Westgate Drive, St. Paul, MN 55114, USA.

Accurate fluid management in microfluidic-based point-of-care testing (POCT) devices is critical. Fluids must be gated and directed in precise sequences to facilitate desired biochemical reactions and signal detection. Pneumatic valves are widely utilized for fluid gating due to their flexibility and simplicity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!