A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Highly Sensitive and Selective Quinazoline-Based Colorimetric Probe for Naked-Eye Detection of Fe Ions. | LitMetric

A novel quinazoline-based colorimetric sensor (probe 1) that detected Fe via naked-eye in a buffered MeOH: HO (8:2) solvent system within a neutral pH range was synthesized and its structure was confirmed by H-NMR, C-NMR, FT-IR, and Mass spectroscopy. Its photophysical properties were also studied. The sensitivity and selectivity factor in the presence of 16 metal ions was examined by utilizing absorption titrations. Based on the selectivity test, probe 1 exhibited excellent selectivity and sensitivity toward Fe ions among various other ions. The competitive effect indicated relatively low interference of other cations on the interaction of probe 1/Fe. To specify the sensing behavior of probe 1 to Fe , the mole ratio method was carried out. After addition of around 500 µL of Fe, the absorption of probe1 reached saturation, and the reaction was completed. The effect of pH on the absorption and stability of probe 1 towards Fe was examined. The pH range from 5.0 to 9.0 was appropriate for detection of Fe. To find the binding stoichiometric of the complex, Job's plot studies were carried out by varying the molar ratio of Fe. A 1:2 binding ratio was proposed. Under the optimal conditions, a good linear relationship (R = 0.9886) was at the concentration of Fe over the range of 50-110 µM, with a detection limit of 47.44 nM. Our quinazoline-based probe has shown good results for the quantitative determination of Fe in samples of urine with high recovery.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10895-022-03016-yDOI Listing

Publication Analysis

Top Keywords

quinazoline-based colorimetric
8
probe
7
highly sensitive
4
sensitive selective
4
selective quinazoline-based
4
colorimetric probe
4
probe naked-eye
4
naked-eye detection
4
ions
4
detection ions
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!