A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

RAM cannula versus short binasal prongs for nasal continuous positive airway pressure delivery in preterm infants: a randomized, noninferiority trial from low-middle-income country. | LitMetric

Unlabelled: To determine if RAM cannula is non-inferior to short binasal prongs (SBP) in providing nasal continuous positive airway pressure (CPAP) in preterm infants with respiratory distress syndrome (RDS). In this randomized, open-label, noninferiority trial from a low-middle-income country, we enrolled 254 preterm infants (28-34 weeks gestational age) with RDS who needed CPAP as primary respiratory support. The eligible infants were randomized to either RAM cannula or SBP interface groups. The primary outcome was CPAP failure (defined as the need for intubation or non-invasive positive pressure ventilation) within 72 h of randomization. The noninferiority margin was defined as a 10% or less absolute difference in CPAP failure rates. The secondary outcomes included nasal trauma and adverse events. We analyzed by per-protocol (primary) and intention to treat. CPAP failure has been seen in 25 infants (19.7%) in the RAM cannula group versus 22 (17.3%) in the SBP group (RD -2.36%; 95% CI -11.9 to 7.2 [beyond inferiority margin]; p = 0.6). Moderate and severe nasal trauma was less in RAM cannula (2.4 vs. 8.7%; RR 0.27; 95% CI 0.08-0.95; p 0.028). Duration of CPAP was also significantly shorter in the RAM cannula group (MD -12.4 h; 95% CI -20.34 to -4.46, p 0.017). There were no differences in other adverse events.

Conclusions: RAM cannula was not non-inferior to SBP in providing CPAP to preterm infants with respiratory distress syndrome.

Trial Registration: Registered at Clinical Trial Registry of India (CTRI/2020/03/024097).

What Is Known: • RAM cannula is used for providing supplemental oxygen therapy. There is conflicting evidence on its efficacy in delivering CPAP support in preterm infants.

What Is New: • RAM cannula was not non-inferior to SBP in providing CPAP to preterm infants with respiratory distress syndrome. • RAM cannula causes less nasal trauma than short binasal prongs.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00431-022-04620-7DOI Listing

Publication Analysis

Top Keywords

ram cannula
40
preterm infants
20
short binasal
12
binasal prongs
12
cannula non-inferior
12
sbp providing
12
cpap preterm
12
infants respiratory
12
respiratory distress
12
cpap failure
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!