A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Fluorescence measurements: importance of G-factor correction, magic angle, and observation wavelengths. | LitMetric

Excitation and emission (observation) conditions heavily impact fluorescence measurements. Both observed spectra and intensity decays (fluorescence lifetimes), when incorrectly measured, may lead to incorrect data interpretations. In this report, we discuss the role of observation conditions in steady-state and time-resolved (lifetime) fluorescence measurements. We demonstrate the importance of the correction for uneven transmissions of vertical and horizontal polarizations of emission light through the detection system. The necessity of using so-called total fluorescence intensity or intensity measured under magic angle (MA) conditions has been demonstrated for both steady-state and time-resolved fluorescence measurements. The dependence of lifetime measurements on observation (emission) wavelengths is also discussed. Two fluorophores, rhodamine 6G (R6G) and 4,4 Dimethylamino-cyano stilbene (DCS) in two solvents - ethanol and glycerol have been used in order to cover a broad range of dye polarities and solvent viscosities.

Download full-text PDF

Source
http://dx.doi.org/10.1088/2050-6120/ac92c5DOI Listing

Publication Analysis

Top Keywords

fluorescence measurements
16
magic angle
8
observation conditions
8
steady-state time-resolved
8
fluorescence
6
measurements g-factor
4
g-factor correction
4
correction magic
4
observation
4
angle observation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!