Purpose: Imaging surveillance following endovascular aneurysm repair (EVAR) is strictly recommended. This study investigates the value of endograft apposition and position relative to the aortic neck on the first postoperative computed tomography angiography (CTA) in determining patients at risk for a late type Ia endoleak (T1aEL).

Materials And Methods: Patients with a T1aEL after the first postoperative CTA were selected from a consecutive database and matched with uncomplicated controls. Endograft apposition and position, including the shortest apposition length (SAL), were determined on the first postoperative CTA. The SAL is the shortest distance between the proximal endograft fabric and the first slice where circumferential apposition with the aortic wall is lost. Differences in endograft apposition at the first postoperative CTA were compared between groups. Logistic regression analysis identified independent predictors for late T1aEL.

Results: A total of 32 patients with a late T1aEL were included and matched with 32 uncomplicated controls. Median follow-up after primary EVAR was 62.0 (interquartile range [IQR]: 36.8, 83.5) months in the T1aEL group compared with 47.5 (IQR: 34.0, 79.3) months in the control group; p=0.265. Median preoperative neck diameter was significantly larger in the T1aEL group than in the control group (26.6 [IQR: 24.9, 29.6] mm versus 23.4 [IQR: 22.5, 25.3] mm); p<0.001. Patients in the T1aEL group had a median SAL of 11.6 (IQR: 4.3, 20.5) mm compared with 20.7 (IQR: 13.1, 24.9) mm in the control group; p=0.002. SAL <10mm on the first postoperative CTA (odds ratio [OR]: 9.63, 95% confidence interval [CI]: 1.60-57.99) and larger neck diameter (OR: 1.80, 95% CI: 1.26-2.57) were independent predictors for developing a late T1aEL.

Conclusion: Preoperative neck diameter and SAL on the first postoperative CTA following EVAR are important predictors for the development of a late T1aEL. Patients with a SAL of <10mm had a significantly higher risk of developing a late T1aEL. Future research should determine whether these patients would benefit from reintervention before an actual T1aEL is present.

Clinical Impact: Understanding the mechanisms of endovascular aneurysm repair failure is essential to further enhance clinical outcomes. Adequate proximal sealing is necessary to foster freedom from type 1a endoleak. This study demonstrates that the shortest apposition length (SAL) at the first postoperative computed tomography angiography (CTA) is able to identify patients at risk for a late type 1a endoleak. Especially patients with a SAL <10mm are at high risk. Currently, the guidelines advice repeated imaging with CTA in patients with a seal <10mm. Future research should determine whether these patients would benefit from re-intervention before an actual type 1a endoleak is present.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10938489PMC
http://dx.doi.org/10.1177/15266028221120514DOI Listing

Publication Analysis

Top Keywords

endograft apposition
12
postoperative cta
12
shortest apposition
8
apposition length
8
postoperative computed
8
computed tomography
8
tomography angiography
8
patients risk
8
late type
8
type endoleak
8

Similar Publications

Prediction of Late Proximal Endoleak Risk after EVAR by Preoperative Estimation of Endograft/Aortic Neck Apposition Surface.

Ann Vasc Surg

January 2025

CHU Rennes, Service de Chirurgie Cardiothoracique et Vasculaire, Rennes, France; INSERM, Rennes, France; Université de Rennes 1, Laboratoire de Traitement du Signal et de l'Image (LTSI), Rennes, France. Electronic address:

Background: The aim of this study was to evaluate a new measurement tool for the preoperative computed tomography (CT) scan to estimate the endograft apposition surface on the proximal aortic neck of the aneurysm that would predict the risk of late type IA endoleak (EL1A).

Methods: From databases of 4 high-volume centers between 2004 and 2020, all patients who underwent Endovascular Aneuruysm Repair (EVAR) with the possibility of analyzing pre and post-EVAR scans and who presented late (>2 years) EL1A in follow-up were included retrospectively (EL1A group). A control group of randomly selected EL1A-free patients were included (control group) and followed-up beyond 4 years.

View Article and Find Full Text PDF

Machine Learning Based Prediction of Post-operative Infrarenal Endograft Apposition for Abdominal Aortic Aneurysms.

Eur J Vasc Endovasc Surg

November 2024

Department of Surgery, Division of Vascular Surgery, University Medical Centre Groningen, Groningen, The Netherlands; Multimodality Medical Imaging Group, Technical Medical Centre, University of Twente, Enschede, The Netherlands.

Objective: Challenging infrarenal aortic neck characteristics have been associated with an increased risk of type Ia endoleak after endovascular aneurysm repair (EVAR). Short apposition (< 10 mm circumferential shortest apposition length [SAL]) on the first post-operative computed tomography angiography (CTA) has been associated with type Ia endoleak. Therefore, this study aimed to develop a model to predict post-operative SAL in patients with an abdominal aortic aneurysm based on the pre-operative shape.

View Article and Find Full Text PDF

Objective: The Gore Excluder Conformable Endoprosthesis (CEXC) is designed to treat challenging infrarenal anatomy because of its active angulation control, repositionability, and enhanced conformability. This study evaluated 30 day and one year position and apposition of the CEXC in the infrarenal neck.

Methods: Patients treated with the CEXC between 2018 and 2022 with an available 30 day computed tomography angiogram (CTA) were selected from four hospitals in a prospective registry.

View Article and Find Full Text PDF
Article Synopsis
  • Total endovascular techniques for treating thoracoabdominal aortic aneurysms can face challenges like endograft migration due to late dilatation of the proximal landing zone.
  • A 55-year-old female patient unfit for open surgery underwent a successful hybrid procedure involving a surgeon-modified fenestrated endovascular graft and thoracoscope-assisted fixation.
  • This innovative approach shows promise for high-risk patients but requires longer follow-up to evaluate its long-term effectiveness.
View Article and Find Full Text PDF

Objective: We compared the outcomes of patients treated with nonbare stents (NBS) and proximal bare stents (PBS) endografts with a proximal landing zone in the aortic arch during thoracic endovascular aortic repair (TEVAR).

Methods: We conducted a retrospective cohort, observational, multicenter study that included 361 consecutive TEVAR procedures undertaken between November 2005 and December 2021. TEVAR patients with both BS and NBS Relay stent graft configurations with proximal landing in zones 1, 2, or 3 were enrolled.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!