Secondary electrospray ionization (SESI) mass spectrometry (MS) is a direct infusion technique often used for untargeted metabolomics, e.g., for online breath analysis. SESI is thought to be a soft ionization method, which is important to avoid interference from in-source fragments and to simplify compound annotation. In this work, benzylammonium ions, formed from volatile benzylamines, with known bond dissociation enthalpies were used as thermometer ions to investigate the internal energy distribution of ions that are produced by SESI. It is shown that SESI is softer than electrospray ionization (ESI), and therefore, SESI indeed qualifies as a soft ionization technique. However, we also found that the standard MS instrument settings used in the SESI community are relatively harsh. Proper soft tuning of the instrument is essential to fully benefit from the softness that SESI can provide. Moreover, there is evidence from in-source collision-induced dissociation (CID) experiments that analytes can be solvated in SESI under soft conditions, which supports a recently proposed SESI mechanism referred to as ligand switching.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/jasms.2c00201 | DOI Listing |
Viruses
November 2024
Laboratório de Imunofarmacologia, Instituto Oswaldo Cruz (IOC), Fundação Oswaldo Cruz (Fiocruz), Rio de Janeiro 21040-361, RJ, Brazil.
Coronavirus disease 2019 (COVID-19) still causes death in elderly and immunocompromised individuals, for whom the sustainability of the vaccine response may be limited. Antiviral treatments, such as remdesivir or molnupiravir, have demonstrated limited clinical efficacy. Nirmatrelvir, an acute respiratory syndrome coronavirus 2 (SARS-CoV-2) major protease inhibitor, is clinically effective but has been associated with viral rebound and antiviral resistance.
View Article and Find Full Text PDFBMC Infect Dis
December 2024
Department of Infectious Diseases and Hospital Epidemiology, University Hospital Zurich, University of Zürich, Zurich, 8097, Switzerland.
Introduction: The ability to detect pathogenic bacteria before the onsets of severe respiratory symptoms and to differentiate bacterial infection allows to improve patient-tailored treatment leading to a significant reduction in illness severity, comorbidity as well as antibiotic resistance. As such, this study refines the application of the non-invasive Secondary Electrospray Ionization-High Resolution Mass Spectrometry (SESI-HRMS) methodology for real-time and early detection of human respiratory bacterial pathogens in the respiratory tract of a mouse infection model.
Methods: A real-time analysis of changes in volatile metabolites excreted by mice undergoing a lung infection by Staphylococcus aureus or Streptococcus pneumoniae were evaluated using a SESI-HRMS instrument.
J Breath Res
December 2024
Department of Pulmonology, University Hospital Zurich, Zurich, Switzerland.
Acute exacerbations of chronic obstructive pulmonary disease (AECOPD) show high variability in individual susceptibility and promote disease progression; thus, accurate diagnosis and treatment is essential. Unravelling the molecular metabolic changes during AECOPD in breath could promote understanding of AECOPD and its treatment. Our objective was to investigate the metabolic breath profiles during AECOPD for biomarker detection.
View Article and Find Full Text PDFMolecules
September 2024
Department of Chemistry "Ugo Schiff", University of Florence, Via della Lastruccia 3-13, 50019 Sesto Fiorentino, FI, Italy.
J Chromatogr A
October 2024
Department of Chemistry and Applied Biosciences, ETHZ, Zurich, Switzerland. Electronic address:
Secondary electrospray ionization coupled to high-resolution mass spectrometry (SESI-HRMS) is a powerful method for the analysis of exhaled breath in real time. However, feature annotation is challenging due to the flow-injection nature of the technique. To evaluate alternative methods for enhancing feature annotation, a study was conducted where the exhaled breath of sixteen subjects was condensed and analyzed using dynamic headspace vacuum in-trap extraction gas chromatography-mass spectrometry (DHS-V-ITEX-GC-MS) and liquid chromatography coupled to mass spectrometry (LC-MS) using polar and reverse-phase conditions along with a data-independent MS-acquisition method based on multiple injections.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!