A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The use of portable OSL and IRSL measurements of NaCl in low dose assessments following a radiological or nuclear emergency. | LitMetric

During recovery phases following a nuclear or radiological incident analyses of doses received by members of the public and responders are often required. Several methods have been investigated for use at different timescales after the incident, including assessments based on measurements of materials present at the time of the incident. Common salt has previously been shown to have potential for retrospective dosimetry in the mGy dose range using laboratory instrumentation. This preliminary study investigates the use of portable instruments, with unprepared commercially sourced salt, in dose ranges below 100 μGy. Responses from pulsed IRSL and portable OSL instruments were compared. For OSL measurements, detection limits of 7 μGy have been demonstrated, with detection limits of 30-340 μGy for the other instruments investigated. Dose responses in the 0-500 μGy range were determined for the most sensitive systems, which show a linear response over this dose range with a non-zero intercept representing doses received from environmental sources since manufacture of the salt. For use as a dosimeter, methods of removing or accounting for inherited signals will be required in this low dose range. The results demonstrate that salt has considerable potential for use in retrospective dosimetry below 100 μGy, and that measurements can be conducted with portable OSL instruments.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9468860PMC
http://dx.doi.org/10.3389/fpubh.2022.969829DOI Listing

Publication Analysis

Top Keywords

portable osl
12
dose range
12
low dose
8
doses received
8
potential retrospective
8
retrospective dosimetry
8
100 μgy
8
osl instruments
8
detection limits
8
dose
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!