Role of catheter location on local impedance measurements and clinical outcome with the new direct sense technology in cardiac ablation procedures.

Int J Cardiol Heart Vasc

Department of Cardiology and Vascular Medicine, West German Heart and Vascular Center Essen, University Duisburg-Essen, Hufelandstrasse 55, 45147 Essen, Germany.

Published: October 2022

Background: A novel catheter technology (direct sense, DS) enables periprocedural local impedance (LI) measurement for estimation of tissue contact during radiofrequency ablation (RFA) for real-time assessment of lesion generation. This measure reflects specific local myocardial conduction properties in contrast to the established global impedance (GI) using a neutral body electrode. Our study aimed to assess representative LI values for the cardiac chambers, to evaluate LI drop in response to RF delivery and to compare those values to established GI measures in patients undergoing RFA procedures.

Methods And Results: Seventy-three patients undergoing RFA with the DS technology were included. Within the cardiac chambers, baseline LI was significantly different, with the highest values in the left atrium (LA 107.5 ± 14.3 Ω; RV 104.6 Ω ± 12.9 Ω; LV 100.7 Ω ± 11.7 Ω, and RA 100.5 Ω ± 13.4 Ω). Baseline LI was positively correlated to the corresponding LI drop during RF delivery (R = 0.26, p = 0.01) representing a promising surrogate of lesion generation. The observed mean LI drop (15.6 ± 9.5 Ω) was threefold higher as GI drop (4.9 ± 7.4 Ω), p < 0.01. We evaluated the clinical outcome in a subgroup of patients undergoing DS-guided pulmonary vein isolation, which was comparable regarding arrhythmia recurrence to a conventional ablation cohort (57 % vs 50 %, p = 0.2).

Conclusion: We provide detailed information on LI measures in electrophysiological procedures with significant differences within the cardiac chambers highlighting that RFA-related LI drop can serve as a promising surrogate for real-time assessment of lesion generation. Guiding the electrophysiologist in RFA procedures, this additional information promises to improve safety profile and success rates in the interventional treatment of arrhythmias.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9468360PMC
http://dx.doi.org/10.1016/j.ijcha.2022.101109DOI Listing

Publication Analysis

Top Keywords

local impedance
8
direct sense
8
lesion generation
8
cardiac chambers
8
patients undergoing
8
undergoing rfa
8
role catheter
4
catheter location
4
location local
4
impedance measurements
4

Similar Publications

Chronic obstructive pulmonary disease (COPD) is a leading cause of death worldwide and greatly reduces the quality of life. Utilizing remote monitoring has been shown to improve quality of life and reduce exacerbations, but remains an ongoing area of research. We introduce a novel method for estimating changes in ease of breathing for COPD patients, using obstructed breathing data collected via wearables.

View Article and Find Full Text PDF

The objective of this study is to investigate the impact of different pH values and chloropropene flow rates on the erosion-corrosion behavior of 316L stainless steel. The influence of various factors on the surface morphology was analyzed using scanning electron microscopy, X-ray powder diffractometry, and electrochemical impedance spectroscopy techniques. The results revealed that at a pH value of 3.

View Article and Find Full Text PDF

Background: Accurate body fat distribution assessment is essential for managing cardiovascular disease and metabolic disorders. Although several methods are available for segmental fat analysis, few studies have examined the validity of affordable methods such as Bioelectrical Impedance Analysis (BIA) against the reference method, Dual-Energy X-ray Absorptiometry (DXA). This study aimed to assess the validity of BIA as compared to DXA for segmental fat mass assessment, and to develop anthropometric multivariate regression models that offer a cost-effective alternative for health professionals in clinical and public health settings.

View Article and Find Full Text PDF

Epithelial tissues in vitro undergo dynamic changes while differentiating heterogeneously on the culture substrate. This gives rise to diverse cellular arrangements which are undistinguished by conventional analysis approaches, such as transepithelial electrical resistance measurement or permeability assays. In this context, solid substrate-based systems with integrated electrodes and electrochemical impedance monitoring capability can address the limited spatiotemporal resolution of traditional porous membrane-based methods.

View Article and Find Full Text PDF

[Effect of extra corporeal reducing pre-load on pulmonary mechanical power in patients with acute respiratory distress syndrome].

Zhonghua Wei Zhong Bing Ji Jiu Yi Xue

December 2024

Department of Public Utilities Development, Henan Provincial People's Hospital, People's Hospital of Zhengzhou University, Zhengzhou 450003, Henan, China.

Objective: To explore the effects of veno-venous extra corporeal carbon dioxide removal (V-V ECCOR) on local mechanical power and gas distribution in the lungs of patients with mild to moderate acute respiratory distress syndrome (ARDS) receiving non-invasive ventilation.

Methods: Retrospective research methods were conducted. Sixty patients with mild to moderate ARDS complicated with renal insufficiency who were transferred to the respiratory intensive care unit (RICU) through the 96195 platform critical care transport green channel from January 2018 to January 2020 at the collaborative hospitals of Henan Provincial People's Hospital were enrolled.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!