Hybrid Closed-Loop Systems to Date: Hype Versus Reality.

Diabetes Technol Ther

Barbara Davis Center for Diabetes, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA.

Published: January 2023

Download full-text PDF

Source
http://dx.doi.org/10.1089/dia.2022.0375DOI Listing

Publication Analysis

Top Keywords

hybrid closed-loop
4
closed-loop systems
4
systems hype
4
hype versus
4
versus reality
4
hybrid
1
systems
1
hype
1
versus
1
reality
1

Similar Publications

Design and experimental study of tillage depth control system for electric rotary tiller based on LADRC.

Sci Rep

January 2025

The Key Laboratory for Agricultural Machinery Intelligent Control and Manufacturing of Fujian Education Institutions, Wuyi University, Nanping, 354300, Fujian, China.

This paper proposes an adaptive real-time tillage depth control system for electric rotary tillers, based on Linear Active Disturbance Rejection Control (LADRC), to improve tillage depth accuracy in tea garden intercropping with soybeans. The tillage depth control system comprises a body posture sensor, a control unit, and a hybrid stepper motor, integrating sensor data to drive the motor and achieve precise depth control. Real-time displacement sensor signals are compared with target values, enabling closed-loop control of the rotary tiller.

View Article and Find Full Text PDF

Introduction: This analysis aimed to investigate diabetes-specific psychological outcomes among adults with type 1 diabetes (T1D) using hybrid closed-loop (HCL) versus standard therapy.

Research Design And Methods: In this multicenter, open-label, randomized, controlled, parallel-group clinical trial, adults with T1D were allocated to 26 weeks of HCL (MiniMed™ 670G) or standard therapy (insulin pump or multiple daily injections without real-time continuous glucose monitoring). Psychological outcomes (awareness and fear of hypoglycemia; and diabetes-specific positive well-being, diabetes distress, diabetes treatment satisfaction, and diabetes-specific quality of life (QoL)) were measured at enrollment, mid-trial and end-trial.

View Article and Find Full Text PDF

To compare glycemic outcomes during and following moderate-intensity exercise (MIE), high-intensity interval exercise (HIE), and resistance exercise (RE) in adolescents with type 1 diabetes (T1D) using a hybrid closed-loop (HCL) insulin pump while measuring additional physiological signals associated with activity. Twenty-eight adolescents (average age 16.3 ± 2.

View Article and Find Full Text PDF

The accuracy of the latest generation Dexcom G7 sensors in individuals with diabetes undergoing hemodialysis has not previously been investigated. Participants with diabetes undergoing hemodialysis were recruited, with paired sensor glucose from Dexcom G7 recorded with plasma glucose analyzed in the laboratory, as well as the Freestyle Precision Pro glucometer and EKF Biosen C-Line analyzer. Ten adults (median age 64.

View Article and Find Full Text PDF

Approach to the Patient using Diabetes Technology in Pregnancy.

J Clin Endocrinol Metab

January 2025

Section of Maternal Fetal Medicine, Obstetrics and Gynecology, University of Chicago.

Diabetes in pregnancy increases risk for complications for the pregnant patient and neonate. Tight glycemic control to maintain glucose levels as close to non-diabetic ranges as possible can lower risk for these complications. Achieving strict glycemic targets can be challenging and technologies including continuous glucose monitors (CGM) and hybrid closed loop (HCL) insulin pumps have the potential to improve diabetes control and pregnancy outcomes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?