Selection methodology of femoral stems under fatigue loading conditions.

Comput Methods Biomech Biomed Engin

Energy, Materials and Environment (GEMA) research group, Universidad de La Sabana, Chía, Cundinamarca, Colombia.

Published: September 2023

The endurance properties of a femoral stem under fatigue loading must be known and the methodology proposed in this work provides the mathematical tools for designers of femoral stems and orthopedic surgeons to select the adequate material and femoral stem design with a new graph that condensate the information in an easy to use selection process. Initially, the theoretical and computational development of the fatigue analysis provides comparable results with an average error of 8.3%. And the formulated methodology with the aim of selecting the mechanical device with the best fatigue performance with an average error of 8.7%.

Download full-text PDF

Source
http://dx.doi.org/10.1080/10255842.2022.2112186DOI Listing

Publication Analysis

Top Keywords

femoral stems
8
fatigue loading
8
femoral stem
8
average error
8
selection methodology
4
femoral
4
methodology femoral
4
fatigue
4
stems fatigue
4
loading conditions
4

Similar Publications

Background: In this study, we estimated the risk of surgically treated postoperative periprosthetic femoral fractures (POPFFs) associated with femoral implants frequently used for total hip arthroplasty (THA).

Methods: In this cohort study of patients who underwent primary THA in England between January 1, 2004, and December 31, 2020, POPFFs were identified from prospectively collected revision records and national hospital records. POPFF incidence rates, adjusting for potential confounders, were estimated for common stems.

View Article and Find Full Text PDF

Background: Transfemoral osseointegrated prostheses, like other uncemented prostheses experience the risk of aseptic loosening and post-operative periprosthetic fractures, with an incidence between 3% and 30%. To date, however, osseointegrated off-the-shelf prostheses are manufactured in a limited number of sizes, and some patients do not meet the strict eligibility criteria of commercial devices. A customized osseointegrated stem was developed and a pre-clinical in vitro investigation of the stem was performed, to evaluate its biomechanical performance.

View Article and Find Full Text PDF

The current study aimed to objectively evaluate the fit of a rectangular, tapered stem to the severely dysplastic hips on the basis of the proximal femoral anatomy and the dimensional properties of the stem. It was hypothesized that the stem size planned with accordance to the diaphyseal canal width alone can accommodate the distal femur successfully with no sizing mismatch. Forty-six patients (53 hips) suffering from secondary osteoarthritis due to hip dysplasia scheduled for total hip arthroplasty (THA) with a subtrochanteric transverse shortening osteotomy were included.

View Article and Find Full Text PDF

Soft tissue-like coupling materials for in vitro acoustic emission studies in total hip arthroplasty.

J Mech Behav Biomed Mater

January 2025

Laboratory for Biomechanics and Biomaterials (LBB), Department of Orthopedic Surgery, Hannover Medical School, Anna-von-Borries-Strasse 1-7, 30625, Hannover, Germany. Electronic address:

In hip arthroplasty, relative movements between the femoral stem and bone can lead to implant loosening, resulting in extensive bone loss. Acoustic emission (AE) analysis is a promising technique for a nondestructive and noninvasive detection of these relative movements. To develop such a detection method, in vitro investigations using piezoelectric AE sensors on implant stems in artificial or human femora are required to characterize the AE signals induced by loosening.

View Article and Find Full Text PDF

Analysis of the protective effect of hydrogen sulfide over time in ischemic rat skin flaps.

Ann Chir Plast Esthet

January 2025

Department of Plastic, Reconstructive, and Aesthetic Surgery, Faculty of Medicine, Çukurova University, Adana, Turkey.

Background: Hydrogen sulfide (HS) is a widely studied gasotransmitter, and its protective effect against ischemia-reperfusion damage has been explored in several studies. Therefore, a requirement exists for a comprehensive study about HS effects on ischemia-reperfusion damage in flap surgery. The aim of this study is to examine the effect of hydrogen sulfide by creating ischemia-reperfusion injury in the vascular-stemmed island flap prepared from the rat groin area.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!