Digital polymerase chain reaction (dPCR) is emerging as a powerful method for nucleic acid detection due to its unprecedented sensitivity and precision. However, most current dPCR platforms are inherently limited by their low multiplexing ability due to primer-pair cross interactions and spectral overlap of available fluorophores. Here, we present a novel and robust method for multiplexing dPCR that is free from primer dimerization and fluorescence channel number limitation, enabling highly precise and multiplexed detection of nucleic acid targets. By prestoring target-specific primers and probes in different storage chambers, the method physically separates reactions and thus avoids the primer-pair cross interactions and spectral overlap of different fluorescent probes that usually occur within a single-tube reaction. Furthermore, a dissolvable delay valve (DDV) is embedded between each pair of the reagent prestorage chamber and reaction microwell array. Such a DDV configuration allows full reconstitution of the prestored reagents and then generates a uniform concentration distribution of the reconstituted reagents across the entire reaction microwell array, which is favorable for achieving reliable and robust multiplex dPCR assays. We demonstrated the feasibility of this method by performing an eight-plex dPCR assay targeting the seven most common point mutations in Kirsten rat sarcoma viral oncogene homologue (KRAS) and a reference sequence (wild-type KRAS allele).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/acs.analchem.2c02920 | DOI Listing |
Metabolites
January 2025
Segal Cancer Proteomics Centre, Lady Davis Institute for Medical Research, Jewish General Hospital, McGill University, Montreal, QC H3T 1E2, Canada.
Quantifying urinary catecholamines and metanephrines is essential for the clinical screening and diagnosis of neuroendocrine tumours. HPLC with electrochemical detection (HPLC-ECD) is commonly used for this type of analysis but requires extensive sample cleanup. Simple and rapid dilute-and-shoot LC-multiple-reaction monitoring (MRM)-MS assays have been developed for quantitating these analytes in urine but have not yet been validated according to the Clinical and Laboratory Standards Institute (CLSI) guidelines.
View Article and Find Full Text PDFScience
January 2025
Program in Cellular and Molecular Medicine, Boston Children's Hospital, Boston, MA, USA.
Single-cell decisions made in complex environments underlie many bacterial phenomena. Image-based transcriptomics approaches offer an avenue to study such behaviors, yet these approaches have been hindered by the massive density of bacterial messenger RNA. To overcome this challenge, we combined 1000-fold volumetric expansion with multiplexed error-robust fluorescence in situ hybridization (MERFISH) to create bacterial-MERFISH.
View Article and Find Full Text PDFNano Lett
January 2025
Department of Electrical and Computer Engineering, University of California, San Diego, 9500 Gilman Drive, La Jolla, California 92093, United States.
Quantitative optical phase information provides an alternative method to observe biomedical properties, where conventional phase imaging fails. Phase retrieval typically requires multiple intensity measurements and iterative computations to ensure uniqueness and robustness against detection noise. To increase the measurement speed, we propose a single-shot quantitative phase imaging method with metasurface optics that can be conveniently integrated into conventional imaging systems with minimal modification.
View Article and Find Full Text PDFSmall
January 2025
Institute of Translational Medicine, The Affiliated Drum Tower Hospital of Nanjing University Medical School, Nanjing, 210008, China.
In this study, we present an ultrasensitive and specific multiplexed detection method for SARS-CoV-2 and influenza (Flu) utilizing CRISPR/Cas13a technology combined with a hydrogel-encapsulated photonic crystal (PhC) barcode integrated with hybridization chain reaction (HCR). The barcodes, characterized by core-shell structures, are fabricated through partial replication of periodically ordered hexagonally close-packed silicon dioxide beads. Consequently, the opal hydrogel shell of these barcodes features abundant interconnected pores that provide a substantial surface area for probe immobilization.
View Article and Find Full Text PDFJ Fluoresc
January 2025
Scientific and Technological Researches Application and Research Center, Duzce University, Duzce, Türkiye.
This study highlights the aqueous synthesis of CdTe/ZnS core/shell quantum dots (QDs) and their application as fluorescence sensors for detecting critical metabolites, including folic acid, glucose, and vitamin C, in real biological samples. The synthesized QDs exhibit excellent quantum efficiency, stability, and biocompatibility, enhanced by mercaptopropionic acid (MPA) ligands, enabling eco-friendly and accurate sensing. Detection limits of 0.