Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
In the present study, the levels and probable public health risks of selected metals (Fe, Mn, Cu, Zn, Ni, Cd and Pb) in nine wheat flour samples collected from Amhara, Oromia, South region, and the Strategic Food Reserve Agency were determined using FAAS and compared with results of prior studies and critical level. The wet digestion method using 65 % HNO and 72 % HClO in 300°C for 3 h was used when preparing the sample. Validation of the optimised digestion method was assessed using the spiking method, and an acceptable percent recovery from all metals. The levels of Fe, Cu, Mn, Zn, Ni and Cd ranged between 8⋅5297 and 11⋅1535, 1⋅633 and 4⋅2346, 3⋅1875 and 8⋅5313, 2⋅3589 and 2⋅7719, 0⋅154 and 0⋅854, and 0⋅0411 and 0⋅216 mg/kg, respectively, for Ethiopian wheat flour, while the level of Fe, Cu, Mn, Zn, Ni, Cd and Pb were ranged between 8⋅0099 and 8⋅1089, 1⋅663 and 1⋅6691, 4⋅5625 and 4⋅6250, 2⋅3015 and 2⋅3072, 0⋅9423 and 1⋅1346, 0⋅1593 and 0⋅1606, and 0⋅13 and 0⋅1381 mg/kg, respectively, for imported wheat flour. However, Pb had a concentration of less than 0⋅043 mg/kg for Ethiopian wheat flour. Findings indicate that Ethiopian wheat is comparatively higher in Fe, Mn, Cu, Zn and Cd, but lower in Ni and Pb than imports. From the result of the study, it can be concluded that the level of heavy metals determined in this study was within the permissible limit, and no probable health risk because both the Hazard quotient (HQ) and the Hazard Index (HI) are found to be below 1⋅0 regarding study metals.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9428666 | PMC |
http://dx.doi.org/10.1017/jns.2022.70 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!