Recent years have shown that the diagnosis and monitoring of biomarkers involved in inflammatory-associated medical conditions such as cancer, neurological disorders, viral infections, or daily physical activities offer real benefits in increasing the quality of medical care and patient life quality. In this context, the use of integrated and portable platforms as point-of-care testing devices for biomedical analysis to enable early disease diagnosis and monitoring, which can be successfully used even at the patient's bed, is an emergency nowadays. The development of low-cost, miniaturized, and portable, user-friendly devices that provide an answer in a timely manner, such as electrochemical sensors, is relevant for the elaboration of point-of-care testing devices. This review focuses on the recent progress in bioanalysis of both specific biomarkers and inflammatory-associated biomarkers present in several diseases like neoplasia, severe neurological disorders, viral infections, and usual physical activity and provides an overview of the state of the art over the most recent electrochemical (bio)sensors for the detection of inflammation-related biomarkers. Future perspectives of point-of-care testing to improve healthcare management are also discussed.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9472196PMC
http://dx.doi.org/10.1007/s00216-022-04320-zDOI Listing

Publication Analysis

Top Keywords

point-of-care testing
12
biomarkers involved
8
inflammatory-associated medical
8
medical conditions
8
diagnosis monitoring
8
neurological disorders
8
disorders viral
8
viral infections
8
testing devices
8
biomarkers
5

Similar Publications

The benefits of using continuous glucose monitoring (CGM) in hospitalized patients with diabetes remain uncertain. Point-of-care (POC) glucose testing is the standard of care in this setting. We compared the effect of adding CGM to POC testing versus POC testing alone on glycemic outcomes in this population.

View Article and Find Full Text PDF

Objective: The objective of this study is to analyse the perspectives of screening candidates and healthcare professionals on shared decision-making (SDM) in prostate cancer (PCa) screening using the prostate-specific antigen (PSA) test.

Design: Descriptive qualitative study (May-December 2022): six face-to-face focus groups and four semistructured interviews were conducted, transcribed verbatim and thematically analysed using ATLAS.ti software.

View Article and Find Full Text PDF

Genetically modified (GM) herbicide-tolerant soybean 'Zhonghuang 6106', which introduces a glyphosate-resistant gene, ensures soybean yield while allowing farmers to reduce the use of other herbicides, thereby reducing weed management costs. To protect consumer rights and facilitate government supervision, we have established a simple and rapid on-site nucleic acid detection method for GM soybean 'Zhonghuang 6106'. This method leverages the isothermal amplification characteristics of RPA technology and the high specificity of CRISPR-Cas12a to achieve high sensitivity and accuracy in detecting GM soybean components.

View Article and Find Full Text PDF

Factors affecting pretransplant muscle strength in allogeneic stem cell transplant candidates prior transplantation.

Support Care Cancer

January 2025

Department of Medical Oncology, Heidelberg University Hospital and National Center for Tumor Diseases Heidelberg, a partnership between German Cancer Research Center (DKFZ) and University Medical Center Heidelberg, Im Neuenheimer Feld 460, 69120, Heidelberg, Germany.

Purpose: Physical performance is crucial for prognosis after allogeneic hematopoietic stem cell transplantation (allo-HCT). Cardiorespiratory fitness has already been shown to have prognostic value, and there is increasing evidence that muscle strength and associated parameters (e.g.

View Article and Find Full Text PDF

Evaluation of point-of-care haemoglobin measurement accuracy in surgery (PREMISE) and implications for transfusion practice: a prospective cohort study.

Br J Anaesth

January 2025

Department of Surgery, The Ottawa Hospital, University of Ottawa, Ottawa, ON, Canada; Clinical Epidemiology Program, Ottawa Hospital Research Institute, Ottawa, ON, Canada. Electronic address:

Background: Point-of-care testing devices to measure haemoglobin (Hgb) frequently inform transfusion decision-making in surgery. This study aimed to examine their accuracy in surgery, focusing on Hgb concentrations of 60-100 g L, a range with higher potential for transfusion.

Methods: This was a prospective diagnostic cohort study focused on method comparison, conducted at two academic hospitals.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!