This report describes a patient with Goldenhar syndrome undergoing anesthesia for whom Macintosh videolaryngoscopy failed, as the epiglottis was adhered to the posterior pharynx and could not be lifted with a tracheal introducer (Cormack-Lehane grade 3B). Hyperangulated videolaryngoscopy revealed only the arytenoids (Cormack-Lehane grade 2B), even after direct lifting of the epiglottis, and endotracheal tube advancement failed due to unclear tissue resistance. Hyperangulated videolaryngoscopy was combined with a tube-mounted camera (VivaSight single lumen tube). The combination of both camera perspectives was successfully used to allow placement of the endotracheal tube underneath the epiglottis and through the vocal cords.

Download full-text PDF

Source
http://dx.doi.org/10.1213/XAA.0000000000001615DOI Listing

Publication Analysis

Top Keywords

hyperangulated videolaryngoscopy
12
patient goldenhar
8
goldenhar syndrome
8
cormack-lehane grade
8
endotracheal tube
8
vivasight single-lumen
4
tube
4
single-lumen tube
4
tube combined
4
combined hyperangulated
4

Similar Publications

Introduction: The number of tracheal intubation attempts required to reach proficiency in videolaryngoscopy with hyperangulated blades is unknown. Understanding this training requirement might guide training for clinicians who perform laryngoscopy. We therefore performed a planned sub-analysis of a randomised controlled trial comparing tracheal intubation success with videolaryngoscopy vs.

View Article and Find Full Text PDF

Aims: This study aimed to compare the efficacy and utility of the McGrath™ videolaryngoscope, using the Macintosh-like McGrath™ MAC blade and the hyperangulated McGrath™ MAC Xblade with a conventional Macintosh blade under simulated resuscitation conditions.

Methods: A prospective, randomized study under conditions mimicking ongoing chest compressions was conducted with 90 anesthesiologists. Intubation success rates, time-to-vocal cords, time-to-intubate, and time-to-ventilate were measured.

View Article and Find Full Text PDF
Article Synopsis
  • Tracheal intubations in the ICU face challenges like poor glottic view and higher complication rates; this study compares the efficacy of two videolaryngoscope (VL) types: the standard Macintosh blade versus a hyperangulated blade.
  • The INtubation VIdeolaryngoscopy BLADE-ICU trial is a randomized, controlled study conducted across 29 ICUs in Spain, focusing on first-attempt intubation success as the primary outcome, along with other measures like time to intubation and complication rates.
  • The study has ethical approval and aims to improve airway management outcomes, with patient enrollment starting in May 2024 and anticipated results to be published in 2025.
View Article and Find Full Text PDF
Article Synopsis
  • Universal use of Storz C-MAC® videolaryngoscopes for adult tracheal intubations was adopted at Royal United Hospitals Bath NHS Foundation Trust in 2017, covering various medical settings, and data was collected from 1,099 procedures between March 2020 and March 2022.
  • The overall intubation success rate was 100%, with a first-pass success rate of 87.3%, varying by device type and user experience, and 87% of attempts resulted in no complications, particularly high in operating theatres and the emergency department.
  • Complications were rare, occurring in only 0.6% of cases, primarily outside theatres and during rapid sequence induction, highlighting the impact of
View Article and Find Full Text PDF