AI Article Synopsis

  • Magic angle spinning NMR offers a unique way to study the dynamics of biomolecules through rotating frame relaxation measurements.
  • The focus is on how motion affects the chemical shift interaction, which is key to understanding relaxation in these experiments.
  • Advances in solid state NMR techniques promise improved analysis, allowing researchers to extract important details like motion time scales and activation energy.

Article Abstract

Magic angle spinning NMR rotating frame relaxation measurements provide a unique experimental window into biomolecules dynamics, as is illustrated by numerous recent applications. We discuss experimental strategies for this class of experiments, with a particular focus on systems where motion-driven modulation of the chemical shift interaction is the main mechanism for relaxation. We also explore and describe common strategies for interpreting the data sets to extract motion time scale, activation energy, and angle or order parameters from rotating frame relaxation data. Using model free analysis and numerical simulations, including time domain treatment, we explore conditions under which it is possible to obtain accurate and precise information about the time scales of motions. Overall, with rapid technical advances in solid state NMR, there is a bright future for this class of studies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10122933PMC
http://dx.doi.org/10.1021/acs.chemrev.2c00442DOI Listing

Publication Analysis

Top Keywords

rotating frame
12
frame relaxation
12
magic angle
8
angle spinning
8
solid state
8
state nmr
8
relaxation
4
relaxation magic
4
spinning solid
4
nmr promising
4

Similar Publications

ORF2p (open reading frame 2 protein) is a multifunctional multidomain enzyme that demonstrates both reverse transcriptase and endonuclease activities and is associated with the pathophysiology of cancer. The 3D structure of the entire seven-domain ORF2p complex was revealed with the recent achievements in structural studies. The different arrangements of the CTD (carboxy-terminal domain) and tower domains were identified as the "closed-ring" and "open-ring" conformations, which differed by the hairpin position of the tower domain, but the structural diversity of these complexes has the potential to be more extensive.

View Article and Find Full Text PDF

Stereotactic systems have traditionally used Cartesian coordinate combined with linear algebraic mathematical models to navigate the brain. Previously, the development of a novel stereotactic system allowed for improved patient comfort, reduced size, and carried through a simplified interface for surgeons. The system was designed with a work envelope and trajectory range optimized for deep brain stimulation applications only.

View Article and Find Full Text PDF

Self-motion is an essential but often overlooked component of sound localisation. As the directional information of a source is implicitly contained in head-centred acoustic cues, that acoustic input needs to be continuously combined with sensorimotor information about the head orientation in order to decode to a world-centred frame of reference. When utilised, head movements significantly reduce ambiguities in the directional information provided by the incoming sound.

View Article and Find Full Text PDF

A Robust Method for Validating Orientation Sensors Using a Robot Arm as a High-Precision Reference.

Sensors (Basel)

December 2024

Antal Bejczy Center for Intelligent Robotics, Obuda University, 1034 Budapest, Hungary.

This paper presents a robust and efficient method for validating the accuracy of orientation sensors commonly used in practical applications, leveraging measurements from a commercial robotic manipulator as a high-precision reference. The key concept lies in determining the rotational transformations between the robot's base frame and the sensor's reference, as well as between the TCP (Tool Center Point) frame and the sensor frame, without requiring precise alignment. Key advantages of the proposed method include its independence from the exact measurement of rotations between the reference instrumentation and the sensor, systematic testing capabilities, and the ability to produce repeatable excitation patterns under controlled conditions.

View Article and Find Full Text PDF

In modern knee arthroplasty, surgeons increasingly aim for individualised implant selection based on data-driven decisions to improve patient satisfaction rates. The identification of an implant design that optimally fits to a patient's native kinematic patterns and functional requirements could provide a basis towards subject-specific phenotyping. The goal of this study was to achieve a first step towards identifying easily accessible and intuitive features that allow for discrimination between implant designs based on kinematic data.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?