The use of head fixation in mice is increasingly common in research, its use having initially been restricted to the field of sensory neuroscience. Head restraint has often been combined with fluid control, rather than food restriction, to motivate behaviour, but this too is now in use for both restrained and non-restrained animals. Despite this, there is little guidance on how best to employ these techniques to optimise both scientific outcomes and animal welfare. This article summarises current practices and provides recommendations to improve animal wellbeing and data quality, based on a survey of the community, literature reviews, and the expert opinion and practical experience of an international working group convened by the UK's National Centre for the Replacement, Refinement and Reduction of Animals in Research (NC3Rs). Topics covered include head fixation surgery and post-operative care, habituation to restraint, and the use of fluid/food control to motivate performance. We also discuss some recent developments that may offer alternative ways to collect data from large numbers of behavioural trials without the need for restraint. The aim is to provide support for researchers at all levels, animal care staff, and ethics committees to refine procedures and practices in line with the refinement principle of the 3Rs.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jneumeth.2022.109705DOI Listing

Publication Analysis

Top Keywords

head fixation
12
fluid/food control
8
neuroscience head
8
refinements rodent
4
head
4
rodent head
4
fixation fluid/food
4
control neuroscience
4
fixation mice
4
mice increasingly
4

Similar Publications

Trends in treatment and epidemiology of radial head fractures.

Shoulder Elbow

January 2025

Rothman Orthopaedics Florida at AdventHealth, Orlando, FL, USA.

Objective: We aimed to assess the recent trends in the demographics of radial head and neck fractures and their management based on displacement.

Methods: TriNetX was queried for cases from 1 January 2017, through 31 December 2022. ICD diagnosis codes were used to define patient cohorts with radial head or neck fractures.

View Article and Find Full Text PDF

Assessment of Speech Processing and Listening Effort Associated With Speech-on-Speech Masking Using the Visual World Paradigm and Pupillometry.

Trends Hear

January 2025

Faculty of Medicine and University Hospital Cologne, Department of Otorhinolaryngology, Head and Neck Surgery, University of Cologne, Cologne, Germany.

Speech-on-speech masking is a common and challenging situation in everyday verbal communication. The ability to segregate competing auditory streams is a necessary requirement for focusing attention on the target speech. The Visual World Paradigm (VWP) provides insight into speech processing by capturing gaze fixations on visually presented icons that reflect the speech signal.

View Article and Find Full Text PDF

During the routine removal of osteosynthesis materials after surgical treatment (ORIF) of condylar head fractures (CHFs), as performed at our clinic, localised and sometimes pronounced intra-articular scarring were observed quite regularly. This prospective study therefore investigates the causes of intra-articular scarring and its impact on functionality after surgical treatment (ORIF) of condylar head fractures (CHFs). Moreover, 80/98 patients with 96/114 CHFs (ORIF between 2014 and 2024) were evaluated when performing hardware removal.

View Article and Find Full Text PDF

Comparison of bioabsorbable screw versus metallic screw fixation for tibial tubercle fractures in adolescents: a retrospective cohort study.

BMC Musculoskelet Disord

January 2025

Department of Orthopedics, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, 100045, China.

Background: Displaced tibial tubercle (TT) fractures in adolescents are typically treated with open reduction and internal fixation. While metallic screw (MS) fixation provides strong stability, it often results in a high incidence of postoperative screw head protrusion or irritation, leading to additional removal surgery. Bioabsorbable screw (BS) fixation presents an alternative that may avoid these issues, though its stability has not yet been extensively documented in the literature.

View Article and Find Full Text PDF

This study aimed to develop a novel reconstruction method for segmental mandibulectomy. In the authors' opinion, reconstruction of the anterior border of the mandibular ramus using a double-arm vascularized fibular flap is important to prevent deformity due to buccal depression and the accumulation of food debris, thereby eliminating masticatory dead space that cannot be filled with prostheses such as implants or dentures. Using conventional reconstruction plates, the reconstructed bone positioned at the anterior border of the mandibular ramus required either fixing with only 1 screw or using 2 plates for stable fixation, making it difficult to position the plates stably.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!