Background: We aimed to evaluate the analytic performance of 3 rapid HIV viral load assays: the novel Xpert HIV-1 VL XC (Xpert XC), Xpert HIV-1 VL (Xpert VL), and m-PIMA HIV-1/2 VL (m-PIMA).

Setting: Two South African clinics.

Methods: We conducted a prospective diagnostic accuracy study. Site-laboratory technicians and nurses used the Xpert XC, Xpert VL, and m-PIMA to test plasma samples from people with HIV receiving antiretroviral therapy. We compared results with the Roche cobas HIV-1 reference assay. We determined accuracy to detect viraemia at the World Health Organization (WHO) failure threshold of 1000 copies/mL on all 3 assays, and 50 and 200 copies/mL on the Xpert assays. We assessed the agreement using Bland-Altman plots.

Results: We enrolled 140 participants (98 [70%] women, median age 37 years), who provided 189 paired samples at one or more timepoints. We tested 174 samples with the Xpert XC, 188 with the Xpert VL, and 128 with the m-PIMA. At 1000 copies/mL, sensitivity and specificity (95% confidence intervals) were 97% (82 to 100) and 98% (93 to 99) (Xpert XC), 100% (87 to 100) and 96% (91 to 98) (Xpert VL), and 92% (72 to 99) and 99% (93 to 100) (m-PIMA) respectively. At 50 copies/mL, sensitivity and specificity were 93% (81 to 98) and 96% (91 to 99) (Xpert XC), and 95% (84 to 99) and 95% (90 to 98) (Xpert VL) respectively. Mean bias was -0.10 (-0.54 to 0.34) log10 copies/mL (Xpert XC), 0.07 (-0.37 to 0.52) log10 copies/mL (Xpert VL), and -0.26 (-0.83 to 0.31) log10 copies/mL (m-PIMA).

Conclusions: In these South African clinics, the accuracy of all 3 assays was clinically acceptable to detect viraemia at the WHO failure threshold, whereas both Xpert assays were also accurate at detecting low-level viraemia.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7613592PMC
http://dx.doi.org/10.1097/QAI.0000000000003037DOI Listing

Publication Analysis

Top Keywords

xpert
18
xpert hiv-1
16
viral load
16
south african
12
copies/ml xpert
12
log10 copies/ml
12
diagnostic accuracy
8
hiv-1 viral
8
m-pima hiv-1/2
8
african clinics
8

Similar Publications

Background: Early and accurate diagnosis of drug resistance, including resistance to second-line anti-tuberculosis (TB) drugs, is crucial for the effective control and management of pre-extensively drug-resistant TB (pre-XDR-TB) and extensively drug-resistant TB (XDR-TB). The Xpert MTB/XDR assay is the WHO recommended method for detecting resistance to isoniazid and second-line anti-TB drugs when rifampicin resistance is detected. Currently, the Xpert MTB/XDR assay is not yet implemented in Ethiopia, thus the MTBDRsl assay continues to be used.

View Article and Find Full Text PDF

Objectives: Evaluation of diagnostic accuracy of two point-of-care (POC) molecular diagnostic tests for the detection of monkeypox virus (MPXV): Xpert® Mpox (Cepheid, Inc., USA) and STANDARD™ M10 MPX/OPX (SD Biosensor, Inc., Korea).

View Article and Find Full Text PDF

Clinical application of time-of-flight mass spectrometry nucleic acid detection technology in diagnosis of drug-resistant pulmonary tuberculosis.

Diagn Microbiol Infect Dis

January 2025

Henan Provincial Chest Hospital tuberculosis within Six/Critical Illness Area, Henan Infectious Diseases(TB)Clinical Research Center, Zhengzhou, Henan, 450001, PR China. Electronic address:

Purpose: This study aims to evaluate the clinical diagnostic value of matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) for tuberculosis and drug-resistant tuberculosis.

Patients And Methods: Totally 201 pulmonary tuberculosis patients were recruited retrospectively. All patients underwent smear microscopy, Mycobacterium growth indicator tube (MGIT) 960 culture, loop-mediated isothermal amplification (LAMP) molecular testing, Xpert MTB/RIF (Xpert), and MassARRAY assay which is a MALDI-TOF MS based method.

View Article and Find Full Text PDF

Background: Tuberculosis (TB) is a leading cause of death worldwide with over 90% of reported cases occurring in low- and middle-income countries (LMICs). Pre-treatment loss to follow-up (PTLFU) is a key contributor to TB mortality and infection transmission.

Objectives: We performed a scoping review to map available evidence on interventions to reduce PTLFU in adults with pulmonary TB, identify gaps in existing knowledge, and develop a conceptual framework to guide intervention implementation.

View Article and Find Full Text PDF

Background: Targeted next-generation sequencing (tNGS) is promising alternative to phenotypic drug susceptibility testing (pDST) for detecting drug-resistant tuberculosis (DRTB). This study explored the potential cost-effectiveness of tNGS for the diagnosis of DR-TB across 3 settings: India, South Africa and Georgia.

Methods: To inform WHO guideline development group (GDG) on tNGS we developed a stochastic decision analysis model and assessed cost-effectiveness of tNGS for DST among rifampicin resistance individuals.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!