A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A study of changes in the heat capacity of carbon nanotube-based ionanofluids prepared from a series of imidazolium ionic liquids. | LitMetric

Ionanofluids (INFs), nanoparticles dispersed into a base fluid, an ionic liquid, are a novel class of alternative heat transfer fluids. Addition of nanoparticles to a base ionic liquid is the prime reason for an enhancement in the thermophysical properties of ionanofluids. However, due to very limited research on ionanofluids, further studies are required to understand changes in the isobaric heat capacity of ionanofluids as a function of size of cations of the base ionic liquid structure and concentration of nanoparticles. Herein, isobaric heat capacity was measured as a function of temperature for the prepared ionanofluid samples from a series of imidazolium ionic liquids and multi walled carbon nanotubes (MWCNTs). Moreover, the influence of the size of cations on the isobaric heat capacity enhancement mechanism and the stability of ionanofluid samples was studied. Furthermore, experimental isobaric heat capacity data were assessed by a novel non-statistical data analysis method named mathematical gnostics (MG). MG marginal analysis was used to evaluate the most probable values from the measured data set. A robust linear regression along a gnostic influence function was also used to find the best fit to correlate the measured data.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d2cp02110bDOI Listing

Publication Analysis

Top Keywords

heat capacity
20
isobaric heat
16
ionic liquid
12
series imidazolium
8
imidazolium ionic
8
ionic liquids
8
base ionic
8
size cations
8
ionanofluid samples
8
measured data
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!