Background And Purpose: Online adaptive MR-guided treatment planning workflows facilitate daily contour adaptation to the actual anatomy. Allocating contour adaptation to radiation therapists (RTTs) instead of radiation oncologists (ROs) might allow for increasing workflow efficiency. This study investigates conformity of adapted target contours provided by dedicated RTTs and ROs.

Materials And Methods: In a simulated online procedure, 6 RTTs and 6 ROs recontoured targets and organs at risk (OAR) in prostate cancer (n = 2), rectal cancer (n = 2) and lymph node-oligometastases (n = 2) cases. RTTs gained contouring competence beforehand by following a specific in-house training program. For all target contours and the reference delineations volumetric differences were determined and Dice similarity coefficient (DSC), conformity index (CI) and generalized CI were calculated. Delineation time and -confidence were registered for targets and OAR. Impact of contour adaptation on treatment plan quality was investigated.

Results: Delineation conformity was generally high with DSC, CI and generalized CI values in the range of 0.81-0.94, 0.87-0.95 and 0.63-0.85 for prostate cancer, rectal cancer and LN-oligometastasis, respectively. Target volumes were comparable for both, RTTs and ROs. Time needed and confidence in contour adaptation was comparable as well. Treatment plans derived with adapted contours did not violate dose volume constrains as used in clinical routine.

Conclusion: After tumor site specific training, daily contour adaptations as needed in adaptive online radiotherapy workflows can be accurately performed by RTTs. Conformity of the derived contours is high and comparable to contours as provided by ROs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9460551PMC
http://dx.doi.org/10.1016/j.tipsro.2022.08.004DOI Listing

Publication Analysis

Top Keywords

contour adaptation
20
prostate cancer
12
rectal cancer
12
online adaptive
8
adaptive mr-guided
8
cancer rectal
8
radiation therapists
8
radiation oncologists
8
daily contour
8
target contours
8

Similar Publications

Animals and humans possess an adaptive ability to rapidly estimate approximate numerosity, yet the visual mechanisms underlying this process remain poorly understood. Evidence suggests that approximate numerosity relies on segmented perceptual units modulated by grouping cues, with perceived numerosity decreasing when objects are connected by irrelevant lines, independent of low-level features. However, most studies have focused on physical objects.

View Article and Find Full Text PDF

Ultraprecision multi-axis CARIC control strategy with application to a nano-accuracy air-bearing motion stage.

ISA Trans

January 2025

State Key Laboratory of Tribology in Advanced Equipment, Department of Mechanical Engineering, Tsinghua University, Beijing, 100084, China; Beijing Key Laboratory of Transformative High-end Manufacturing Equipment and Technology, Tsinghua University, Beijing, 100084, China. Electronic address:

Multi-axis contouring control is crucial for ultraprecision manufacturing industries, contributing to meeting the ever-increasingly stringent performance requirements. In this article, a novel contouring adaptive real-time iterative compensation (CARIC) method is proposed to achieve extreme multi-axis contouring accuracy, remarkable trajectory generalization, disturbance rejection, and parametric adaptation simultaneously. Specifically, control actions generated by CARIC consist of robust feedback, adaptive feedforward, and online trajectory compensation components.

View Article and Find Full Text PDF

Purpose: Ultrahypofractionation presents challenges for a subset of high-risk prostate cancer patients due to the large planning target volume (PTV) margin required for the seminal vesicles. Online adaptive radiation therapy could potentially reduce this margin. This paper focuses on the development, preclinical validation, and clinical testing of online adaptive robotic stereotactic body radiation therapy for this patient group.

View Article and Find Full Text PDF

MR-linac: role of artificial intelligence and automation.

Strahlenther Onkol

January 2025

Department of Radiation Oncology, University Hospital Zurich, University of Zurich, Rämistrasse 100, 8091, Zurich, Switzerland.

The integration of artificial intelligence (AI) into radiotherapy has advanced significantly during the past 5 years, especially in terms of automating key processes like organ at risk delineation and treatment planning. These innovations have enhanced consistency, accuracy, and efficiency in clinical practice. Magnetic resonance (MR)-guided linear accelerators (MR-linacs) have greatly improved treatment accuracy and real-time plan adaptation, particularly for tumors near radiosensitive organs.

View Article and Find Full Text PDF

Transvestibular Chondrolarynoplasty-Experimental Study in Cadavers.

J Voice

January 2025

Universidade Federal de São Paulo - UNIFESP, 04023-062, São Paulo, São Paulo State, Brazil. Electronic address:

Background: The neck, and specifically the prominence of the thyroid cartilage, can be considered a marker of male gender, which is often unwanted by transgender women. Chondrolaryngoplasty is traditionally performed using an open transcervical approach, which, while effective, leaves visible scars that can compromise patient satisfaction. Recent advancements, such as the transoral endoscopic vestibular approach (TOEVA), have emerged as promising alternatives, eliminating external scars and improving esthetic outcomes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!