With heart failure (HF) and renal malfunction becoming global public health issues, there is an urgent need to monitor diseases at home or in the community. Point-of-care testing (POC) would shorten the patients waiting time compared with laboratory molecular analysis. This work evaluates two types of gold nanomaterials, and two assay protocols, to develop a lateral flow (LF) system for Cystatin C (CysC) quantification. Of the protocols, the 'delayed-release' shows the alleviation of the hook effects with 1% BSA running buffer (RB), albeit at increased complexity with three steps of washing. The standard method with sample dilution (1: 150 sample dilution for GNPs, and 1:10 sample dilution for GNRs) can ensure the clinical range detection of CysC as 1 mg/L with partial LF assays. GNPs have stronger optical signal intensity compared with GNRs and developed full LF assays with GNPs require 1:1.5 sample dilution in recombinant Cys C detection. The ideal sample dilution ratio is different for partial and full LF assays. Clinical Relevance- This work is the basis of future work that will use LF devices for human serum/plasma monitoring to assess kidney function related to heart failure during medication. The specificity, sensitivity, and limit of detection will be validated via a clinical trial before potential clinical use.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/EMBC48229.2022.9871131 | DOI Listing |
Methods Mol Biol
January 2025
Department of Biochemistry, University of Toronto, Toronto, ON, Canada.
Negative staining electron microscopy is one of the easiest ways to determine the shape and dimensions of multimeric protein complexes over 100 kDa molecular weight. This method requires small volumes (< 10 μL) of dilute protein (0.01-0.
View Article and Find Full Text PDFSci Rep
January 2025
School of Public Health, Jining Medical University, Jining, 272067, People's Republic of China.
Aptamers have shown potential for diagnosing clinical markers and targeted treatment of diseases. However, their limited stability and short half-life hinder their broader applications. Here, a real sample assisted capture-SELEX strategy is proposed to enhance the aptamer stability, using the selection of specific aptamer towards PD-L1 as an example.
View Article and Find Full Text PDFInt J Legal Med
January 2025
Division of Forensic Medicine and Toxicology, Department of Pathology, Faculty of Health Science, University of Cape Town, Cape Town, South Africa.
The ForenSeq™ DNA Signature Prep kit has not been thoroughly tested with crude buccal swab lysates in large-scale population studies using massively parallel sequencing (MPS). Commonly used lysis buffers for swabs intending to undergo direct polymerase chain reaction (PCR) are SwabSolution™ and STR GO! Lysis Buffers, and these have been successfully used to generate population data using capillary electrophoresis (CE) systems. In this study, we investigated the performance and optimisation of SwabSolution™ and STR GO! lysates with the ForenSeq™ DNA Signature Prep workflow and addressed the challenge of failed MPS profiles in initial trials.
View Article and Find Full Text PDFAnal Methods
January 2025
Otolaryngology, Head and Neck Surgery Department of Fujian Provincial Hospital, Provincial Clinical Medical College of Fujian Medical University, Fuzhou University Affiliated Provincial Hospital, Fuzhou, Fujian, 35001, China.
Pepsin serves as a potential biomarker for laryngopharyngeal reflux disease (LPRD). The reported methods for detecting pepsin still have limitations, such as long reaction times and low sensitivity. Therefore, it is crucial to develop a rapid, simple and sensitive detection method.
View Article and Find Full Text PDFAnal Chim Acta
February 2025
Department of Biochemistry and Molecular Biology, Chang Gung University, Taoyuan, 333, Taiwan; Clinical Proteomics Core Laboratory, LinKou Chang Gung Memorial Hospital, Taoyuan, 333423, Taiwan. Electronic address:
Background: Tissue metabolomics analysis, alongside genomics and proteomics, offers crucial insights into the regulatory mechanisms of tumorigenesis. To enhance metabolite detection sensitivity, chemical isotope labeling (CIL) techniques, such as dansylation, have been developed to improve metabolite separation and ionization in mass spectrometry (MS). However, the dissolution of hydrophobic derivatized metabolites in solvents with high acetonitrile content limits the use of liquid chromatography (LC) systems with small-volume reversed-phase (RP) columns.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!