Screening for atrial fibrillation (AF) could reduce the incidence of stroke by identifying undiagnosed AF and prompting anticoagulation. However, screening may involve recording many electrocardiograms (ECGs) from each participant, several of which require manual review which is costly and time-consuming. The aim of this study was to investigate whether the number of ECG reviews could be reduced by using a model to prioritise ECGs for review, whilst still accurately diagnosing AF. A multiple logistic regression model was created to estimate the likelihood of an ECG exhibiting AF based on the mean RR-interval and variability in RR-intervals. It was trained on 1,428 manually labelled ECGs from 144 AF screening programme participants, and evaluated using 11,443 ECGs from 1,521 participants. When using the model to order ECGs for review, the number of reviews for AF participants was reduced by 74% since no further reviews are required after an AF ECG is identified; however, it did not impact the number of reviews in non-AF participants (the vast majority of participants), so the overall number of reviews was reduced by 3% with no missed AF diagnoses. When using the model to also exclude ECGs from review, the overall number of reviews was reduced by 28% with no missed AF diagnoses, and by 53% with only 4% of AF diagnoses missed. In conclusion, the workload can be reduced by using a model to prioritise ECGs for review. Ordering ECGs alone only provides only a moderate reduction in workload. The additional use of a threshold to exclude ECGs from review provides a much greater reduction in workload at the expense of some missed AF diagnoses. Clinical Relevance-This shows the potential benefit of using a model to prioritise electrocardiograms for review in order to reduce the manual workload of AF screening.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC48229.2022.9871092DOI Listing

Publication Analysis

Top Keywords

ecgs review
20
number reviews
16
reviews reduced
12
model prioritise
12
missed diagnoses
12
ecgs
9
review
8
manual review
8
atrial fibrillation
8
reduced model
8

Similar Publications

Background: Cardiovascular disease remains the leading cause of mortality worldwide. Cardiac fibrosis impacts the underlying pathophysiology of many cardiovascular diseases by altering structural integrity and impairing electrical conduction. Identifying cardiac fibrosis is essential for the prognosis and management of cardiovascular disease; however, current diagnostic methods face challenges due to invasiveness, cost, and inaccessibility.

View Article and Find Full Text PDF

Is it possible to monitor fetal movements with a wearable device? A review of novel technologies.

Eur J Obstet Gynecol Reprod Biol

December 2024

Institute of Reproductive Developmental Biology, Department of Metabolism Digestion and Reproduction, Hammersmith Campus, Imperial College London, London, W12 0HS, United Kingdom. Electronic address:

Article Synopsis
  • Stillbirth is often linked to decreased fetal movements, but current methods for tracking these movements lack accuracy and can lead to unnecessary medical interventions.
  • New technologies, including electrocardiography and accelerometry, are being developed to provide more objective and reliable quantification of fetal movements.
  • The review highlights the need for improved fetal movement monitoring solutions that allow pregnant women to maintain their daily activities while ensuring their baby's wellbeing is effectively monitored.
View Article and Find Full Text PDF

Background: Wide QRS complex tachycardia (WCT) differentiation into ventricular tachycardia (VT) and supraventricular wide complex tachycardia (SWCT) remains challenging despite numerous 12-lead electrocardiogram (ECG) criteria and algorithms. Automated solutions leveraging computerized ECG interpretation (CEI) measurements and engineered features offer practical ways to improve diagnostic accuracy. We propose automated algorithms based on (i) WCT QRS polarity direction (WCT Polarity Code [WCT-PC]) and (ii) QRS polarity shifts between WCT and baseline ECGs (QRS Polarity Shift [QRS-PS]).

View Article and Find Full Text PDF

Proper management of cattle reproduction has a major impact on the efficiency and profitability of dairy production. Ultrasound examination and transrectal palpation or the pregnancy-associated glycoprotein (PAG) test are currently the most commonly used methods for pregnancy diagnosis. However, alternative methods to those mentioned above are constantly being sought in order to minimise stress during the examination, the cost of veterinary services and to reduce the rate of errors in pregnancy diagnosis.

View Article and Find Full Text PDF

Background/aim: Final diagnosis of heart failure (HF) relies on a combination clinical findings, laboratory and imaging tests. The aim of this study was to review the diagnostic approach to HF in Türkiye.

Materials And Methods: This study is a subanalysis of the nationwide TRends-HF study, based on anonymized data from National Electronic Database between January 1, 2016, and December 31, 2022.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!