Local pulse wave velocity (PWV) has gained much attention in the last decade due to its ability to provide localized stiffness information from a target vessel and cater to several applications beyond regional PWV. Transit time-based methods are the most straightforward, but their reliability is highly dependent on the blood pulse sensing modality. Conventional ultrasound systems directly measure the blood pulse (as diameter or flow velocity); however, they offer limited frame rates resulting in poor resolution signals. Advanced systems supporting high frame rates are expensive, complex, and not amenable to field and resource-constraint settings. We have developed a high frame image-free ultrasound system to address this gap for automated and online measurement of local PWV. In an earlier in-vitro study, we have demonstrated its accuracy. In this work, we aim to investigate its in-vivo reliability. A study on 15 young, healthy subjects was conducted to assess the intra-and inter-operator repeatability of the developed system. The yielded local PWVs from the left carotid artery were within the range of 2.5 to 5.8 m/s. The device provided highly repeatable intra- and inter-operator measurements with ICC of 0.94 and 0.88, respectively. The bias for the intra- and inter-operator trials was statistically negligible (p > 0.005). The study demonstrated the potential of the high frame rate device to perform reliable measurements in-vivo. Clinical Relevance- This work aims to provide and validate an easy-to-use affordable and fully-automated high frame rate ultrasound technology for the measurement of online local PWV that is currently lacking.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC48229.2022.9871607DOI Listing

Publication Analysis

Top Keywords

high frame
16
pulse wave
8
wave velocity
8
image-free ultrasound
8
blood pulse
8
frame rates
8
local pwv
8
study demonstrated
8
intra- inter-operator
8
frame rate
8

Similar Publications

Near-Field Clutter Mitigation in Speckle Tracking Echocardiography.

Ultrasound Med Biol

January 2025

Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong; Biomedical Engineering Programme, The University of Hong Kong, Hong Kong. Electronic address:

Objective: Near-field (NF) clutter filters are critical for unveiling true myocardial structure and dynamics. Randomized singular value decomposition (rSVD) stands out for its proven computational efficiency and robustness. This study investigates the effect of rSVD-based NF clutter filtering on myocardial motion estimation.

View Article and Find Full Text PDF

Deep Equilibrium Unfolding Learning for Noise Estimation and Removal in Optical Molecular Imaging.

Comput Med Imaging Graph

January 2025

CAS Key Laboratory of Molecular Imaging, Institute of Automation, Chinese Academy of Sciences, Beijing 100190, China; School of Artificial Intelligence, University of Chinese Academy of Sciences, Beijing 100049, China; National Key Laboratory of Kidney Diseases, Beijing 100853, China. Electronic address:

In clinical optical molecular imaging, the need for real-time high frame rates and low excitation doses to ensure patient safety inherently increases susceptibility to detection noise. Faced with the challenge of image degradation caused by severe noise, image denoising is essential for mitigating the trade-off between acquisition cost and image quality. However, prevailing deep learning methods exhibit uncontrollable and suboptimal performance with limited interpretability, primarily due to neglecting underlying physical model and frequency information.

View Article and Find Full Text PDF

Background: Virtual interviewing for fellowship training programs has been widely adopted since the COVID-19 pandemic. However, whether fellowship candidates can adequately evaluate training program culture through virtual interviews is unclear.

Objective: Our aim was to explore how pulmonary and critical care fellows ascertained program culture during virtual and in-person fellowship program recruitment interviews, with the overall goal of improving our virtual recruiting interview processes.

View Article and Find Full Text PDF

Importance: As US health care systems shift to human papillomavirus (HPV)-based cervical cancer screening, more patients are receiving positive high-risk non-16/18 genotype HPV results and negative for intraepithelial lesion or malignancy (NILM) cytological findings. Risk-based management guidelines recommend 2 consecutive negative annual results to return to routine screening.

Objective: To quantify patterns of surveillance testing and associated outcomes for patients after an HPV-positive results and NILM cytologic findings.

View Article and Find Full Text PDF

Sequence analysis and genome organization of a new marafivirus from Leptochloa chinensis.

Arch Virol

January 2025

State Key Laboratory of Ecological Pest Control for Fujian and Taiwan Crops, Fujian Agriculture and Forestry University, Fuzhou, 350002, Fujian, China.

High-throughput sequencing was used to identify and characterize a novel marafivirus from the weed Leptochloa chinensis, which was tentatively named "Leptochloa chinensis marafivirus" (LcMV). The complete genome of the virus consists of 6,178 base pairs, and its nucleotide sequence is 73.82% identical to that of Sorghum almum marafivirus, which is a member of the genus Marafivirus within the family Tymoviridae.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!