A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Detection Limits of Tetrapolar Impedance Sensors for Tissue Differentiation. | LitMetric

Cancer recurrence is an important issue in bladder tumor resections, because tissue cannot generously be removed from the thin bladder wall without impacting its functionality. Electrical impedance measurements during an operation aim to support the surgeon in making the decision which tissue areas to preserve, because physiological changes in tissue due to cancerous mutations can be detected by their altered electrical characteristics. This work investigates the detection limits of tetrapolar sensors when the impedance of heterogeneous tissue is measured. To do this, a finite element analysis is carried out where the sensors are placed on a dielectric medium with inclusions of different sizes, conductivity, and locations relative to the sensor. It is shown that a sensor with four electrodes in a square performs poorly in comparison to a sensor where the electrodes are symmetrically shaped as rings around one center electrode. This is mainly due to its enlarged regions of negative sensitivity. Based on the results, a third, optimized sensor geometry is proposed that shows superior performance to the other sensors in terms of geometry factor, sensitivities, and tumor detection. In simulation, it can reliably detect tumors with only half the radius of the sensor surface. Smaller tumor fractions cannot be detected by either sensor.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC48229.2022.9871065DOI Listing

Publication Analysis

Top Keywords

detection limits
8
limits tetrapolar
8
sensor electrodes
8
sensor
6
tissue
5
tetrapolar impedance
4
sensors
4
impedance sensors
4
sensors tissue
4
tissue differentiation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!