A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Proximal junctional failure after surgical instrumentation in adult spinal deformity: biomechanical assessment of proximal instrumentation stiffness. | LitMetric

Proximal junctional failure after surgical instrumentation in adult spinal deformity: biomechanical assessment of proximal instrumentation stiffness.

Spine Deform

Department of Mechanical Engineering, Polytechnique Montréal, Downtown Station, P.O. Box 6079, Montreal, QC, H3C 3A7, Canada.

Published: January 2023

Study Design: Assessment of different proximal instrumentation stiffness features to minimize the mechanical proximal junctional failure-related risks through computer-based biomechanical models.

Objective: To biomechanically assess variations of proximal instrumentation and loads acting on the spine and construct to minimize proximal junctional failure (PJF) risks. The use of less-stiff fixation such as hooks or tensioned bands, compared to pedicle screws, at the proximal instrumentation level are considered to allow for a gradual transition in stiffness with the adjacent levels, but the impact of such flexible fixation on the loads balance and complications such as PJF remain uncertain.

Methods: Six patients with adult spine deformity who underwent posterior spinal instrumentation were used to numerically model and simulate the surgical steps, erected posture, and flexion functional loading in patient-specific multibody analyses. Three types of upper-level fixation (pedicle screws (PS), supralaminar hooks (SH), and sublaminar bands (SB) with tensions of 50, 250, and 350 N) and rod stiffness (CoCr/6 mm, CoCr/5.5 mm, Ti/5.5 mm) were simulated. The loads acting on the spine and implants of the 90 simulated configurations were analyzed using Kruskal-Wallis statistical tests.

Results: Simulated high-tensioned bands decreased the sagittal moment at the adjacent level proximal to the instrumentation (1.3 Nm at 250 N; 2.5 Nm at 350 N) compared to screws alone (PS) (15.6 Nm). At one level above, the high-tensioned SB increased the sagittal moment (17.7 Nm-SB vs. 15.5 Nm-PS) and bending moment on the rods (5.4 Nm and 5.7 Nm vs. 0.6 Nm) (p < 0.05). SB with 50 N tension yielded smaller changes in load transition compared to higher tension, with moments of 8.1 Nm and 16.8 Nm one and two levels above the instrumentation. The sagittal moment at the upper implant-vertebra connection decreased with the rod stiffness (1.0 Nm for CoCr/6 mm vs. 0.7 Nm for Ti/5.5 mm; p < 0.05).

Conclusion: Simulated sublaminar bands with lower tension produced smaller changes in the load transition across proximal junctional levels. Decreasing the rod stiffness further modified these changes, with a decrease in loads associated with bone failure, however, lower stiffness did increase the rod breakage risk.

Level Of Evidence: N/A.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s43390-022-00574-wDOI Listing

Publication Analysis

Top Keywords

proximal instrumentation
20
proximal junctional
12
proximal
8
junctional failure
8
assessment proximal
8
instrumentation stiffness
8
loads acting
8
acting spine
8
pedicle screws
8
sagittal moment
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!