A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Practical Fast-Response Anodized-Aluminum Pressure-Sensitive Paint Using Chemical Adsorption Luminophore as Optical Unsteady Pressure Sensor. | LitMetric

Practical Fast-Response Anodized-Aluminum Pressure-Sensitive Paint Using Chemical Adsorption Luminophore as Optical Unsteady Pressure Sensor.

Sensors (Basel)

Department of Aerospace Engineering, Graduate School of Engineering, Tohoku University, 6-6-01 Aramakiaza-Aoba, Aoba-ku, Sendai 980-8579, Japan.

Published: August 2022

We developed and evaluated an anodized-aluminum pressure-sensitive paint (AA-PSP) with new formulations of free-base porphyrin, H2TCPP, as an optical unsteady pressure sensor. The luminophore H2TCPP has quite a short fluorescent lifetime (2.4 ns on the condition of the AA-PSP). The fluorescence spectroscopy result shows that the excitation wavelength of H2TCPP corresponds to violet-colored (425 nm) and green-colored (longer than 520 nm) lights. The pressure sensitivity is sufficiently high for the pressure sensor (0.33-0.51%/kPa) and the temperature sensitivity is very low (0.07-1.46%/K). The photodegradation of the AA-PSPs is not severe in both excitation light sources of the green LED and the Nd:YAG laser. The resonance tube experiment result shows the cut-off frequency of the AA-PSPs is over 9.0 kHz, and the results of the shock tube experiment show the 10 µs order time constant of the normal shock wave.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9460456PMC
http://dx.doi.org/10.3390/s22176401DOI Listing

Publication Analysis

Top Keywords

pressure sensor
12
anodized-aluminum pressure-sensitive
8
pressure-sensitive paint
8
optical unsteady
8
unsteady pressure
8
tube experiment
8
practical fast-response
4
fast-response anodized-aluminum
4
paint chemical
4
chemical adsorption
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!