Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The vast majority of transcatheter valve-in-valve (ViV) mitral procedures have been reported with the SAPIEN family. We aimed to report the preliminary experience with the Myval balloon-expandable device in this setting. Multicenter retrospective study of high-risk surgical patients with mitral bioprosthesis degeneration undergoing transcatheter ViV implantation with Myval device. A total of 11 patients from five institutions were gathered between 2019 and 2022 (age 68 ± 7.8, 63% women). The peak and mean transvalvular gradients were 27 ± 5 mmHg and 14.7 ± 2.3 mmHg, respectively, and the predicted neo-left ventricular outflow tract (neo-LVOT) area was 183.4 ± 56 mm (range: 171 to 221 mm). The procedures were performed via transfemoral access in all cases (through echocardiography-guided transeptal puncture (81.8% transesophageal, 11.2% intracardiac)). Technical success was achieved in all cases, with no significant residual mitral stenosis in any of them (peak 7.2 ± 2.7 and mean gradient 3.4 ± 1.7 mmHg) and no complications during the procedure. There were no data of LVOT obstruction, migration, or paravalvular leak in any case. Mean hospital stay was 3 days, with one major vascular complication and no stroke. At 6-month follow-up, there was one case with suboptimal anticoagulation presenting an increase in the transmitral gradients (mean 15 mmHg) that normalized after optimization of the anticoagulation, but no other relevant events. Transseptal ViV mitral implantation with the balloon-expandable Myval device was feasible and safe avoiding redo surgery in high-risk patients with bioprosthesis degeneration.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9457220 | PMC |
http://dx.doi.org/10.3390/jcm11175210 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!